# The PLUS study: efficacy of triclosan coated suture (VicrylPlus®) to reduce infection in primary suture of childbirth related perineal tears - a randomized controlled trial

**Authors:** K. Sonnichsen, P-E. Isberg, J. Elers, M. Zaigham, Nana Wiberg

PMC · DOI: 10.1186/s40748-025-00211-0 · 2025-05-05

## TL;DR

A study found that triclosan-coated sutures reduce infection risk in childbirth-related perineal tears, except for minor tears.

## Contribution

Demonstrates that triclosan-coated sutures significantly lower infection rates in deeper perineal tears during childbirth recovery.

## Key findings

- Triclosan-coated sutures reduced infection rates by 43% in deeper perineal tears.
- First-degree tears showed a non-significant increase in infection with triclosan-coated sutures.
- Second-degree tears had a significant reduction in infection using triclosan-coated sutures.

## Abstract

Preventing infection in primary sutured perineal tears after childbirth is crucial to avoid systemic antibiotic use and potential complications from poor healing. This study aimed to investigate the efficacy of an antibacterial, triclosan-coated suture (VicrylPlus®) in reducing infection in primary sutured childbirth-related perineal tears.

The PLUS study was a single-center, single-blinded, adaptive parallel-group randomized trial conducted at Lund University Hospital, Sweden. Women aged ≥ 18 years with a perineal tear at childbirth were randomly assigned in a 1:1 ratio to either the control group (conventional-absorbable suture, Vicryl®) or the intervention group (triclosan-coated- absorbable suture, VicrylPlus®).

Out of 1921 eligible women, 1890 were randomized to either Vicryl® (n = 953) or VicrylPlus® (n = 937). There were no significant demographic differences between the groups. The most common type of tear in both groups was a second-degree tear (Vicryl® 66.2% (n = 625), VicrylPlus® 67.5% (n = 625)). Encompassing all types of deeper tears in the analysis there was a significantly decrease in infection after suturing with VicrylPlus® 4% (n = 28) versus Vicryl® 6.8% (n = 47); (OR 0.57, 95% CI 0.35–0.91, P = 0.024). When analyzing different tears separately, there was a non-significant increase in infection for first-degree tears with VicrylPlus® 0.8% (n = 2) versus Vicryl® 3.9% (n = 8); (OR 4.75, 95% CI 1.00-22.63, P = 0.050). However, for second-degree tears, the infection rate was significantly reduced with VicrylPlus® 4.4% (n = 27) versus Vicryl® 7.2% (n = 44); (OR 0.63, 95% CI 0.36–0.98, P = 0.05) and for third-degree and unclassified tears there was a non-significant decrease in infections with VicrylPlus® 5.3% (n = 1) versus Vicryl® 14.3% (n = 2); (OR 0.33, 95% CI 0.03–4.10, P = 0.561), respectively, VicrylPlus® 0% versus Vicryl® 1.7% (n = 1); (OR 0.98, 95% CI 0.95–1.02, P = 0.462).

The use of triclosan coated sutures significantly reduces the risk of infection in primary sutured childbirth-related perineal tears by 43%, except for first-degree tears. Further research is needed to determine whether their effectiveness remains consistent across the other specific types of deeper tears in a larger study population.

ClinicalTrials (NCT02863874), posted 11/08/2016, retrospectively registered. Approved by the regional ethical committee before start of enrollment (Dnr 2015/774).

The online version contains supplementary material available at 10.1186/s40748-025-00211-0.

## Linked entities

- **Chemicals:** triclosan (PubChem CID 5564)

## Full-text entities

- **Diseases:** tear (MESH:D012167), perineal tear (MESH:D009437), infection (MESH:D007239)
- **Chemicals:** Vicryl (MESH:D011098), VicrylPlus (-), triclosan (MESH:D014260)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

1 figure with captions in the complete paper: https://tomesphere.com/paper/PMC12051262/full.md

---
Source: https://tomesphere.com/paper/PMC12051262