# Characterization of Individuals with High-Frequency Artificial Tear Supplement Use

**Authors:** Wan-Lin Wu, Shu-Wen Chang

PMC · DOI: 10.3390/jcm14082694 · 2025-04-15

## TL;DR

This study identifies factors linked to frequent use of artificial tears in dry eye patients and finds that high users have worse symptoms and more severe eye conditions.

## Contribution

The study identifies specific clinical parameters and symptom scores associated with high-frequency artificial tear use in dry eye patients.

## Key findings

- High users had significantly higher symptom scores and more severe corneal staining compared to low users.
- High users were more likely to receive cyclosporine treatment during follow-up.
- Environmental triggers may contribute to hyperalgesia in high users.

## Abstract

Objectives: We aimed to investigate dry eye parameters as potential predisposing factors and estimate the prevalence of high-frequency topical eye drop usage. Methods: A total of 5594 dry eye patients treated between November 2015 and June 2022 were included. High users (n = 180) were those who applied at least one artificial tear drop per hour, whereas those who used artificial tears fewer than four times daily were classified as low users (n = 5414). Differences in self-reported symptoms (OSDI, SPEED questionnaires) and tear-related parameters, including severity of corneal staining (SPK), fluorescein tear-film break-up time (FTBUT), lipid layer thickness (LLT), number of expressible meibomian glands (MGE), meiboscale, and blink patterns, were assessed. Subsequent follow-up comprehensive dry eye assessments were performed at 3 months. Results: There was no difference in age or sex between high users and low users (p = 0.075 and 0.508, respectively). High users had significantly higher symptom scores (p < 0.001), more total blinks (p = 0.001), lower Schirmer scores (p < 0.001), higher SPK grades (p < 0.001), shorter FTBUT (p = 0.010), and higher limbal redness scores (p = 0.002). However, there were no differences in the LLT, MGE, or meiboscale. The compliance with follow-up examinations at 3 months was significantly greater for the high users (p < 0.001). Patients with OSDI scores > 40, SPEED scores > 12, Schirmer scores ≤ 3 mm, and higher compliance with follow-up examinations had odds ratios of 4.0, 3.3, 1.7, and 4.1, respectively, for being high users (95% confidence intervals = 2.8–5.8, 2.4–4.7, 1.2–2.3 and 2.7–5.2, respectively). Among the high users, reducing topical drops significantly decreased the SPEED and OSDI scores, except for the environmental trigger factor in the OSDI questionnaire. During long-term follow-up, 1.1% of low users and 15.4% of high users received cyclosporine treatment (odds ratio 16.4, p < 0.001). Conclusions: OSDI scores > 40, SPEED scores > 12, and Schirmer scores ≤ 3 mm were associated with high-frequency eye drop usage, which accounted for 3.2% of moderate to severe dry eye patients. Susceptibility to environmental triggers could represent hyperalgesia/allodynia in high users. High users have a higher need for cyclosporine treatment.

## Linked entities

- **Diseases:** dry eye (MONDO:0006733)

## Full-text entities

- **Diseases:** eye drop (MESH:D020427), allodynia (MESH:D006930), dry eye (MESH:D015352)
- **Chemicals:** meiboscale (-), cyclosporine (MESH:D016572)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12027582/full.md

---
Source: https://tomesphere.com/paper/PMC12027582