# Surgical Robots Improve Tunnel Angle and Graft Bending Angle in Anatomic ACL Reconstruction: A Multicenter Study

**Authors:** Ling Zhang, Hansheng Hu, Wennuo Huang, Mengling Hu, Zhuman Li, Jinzhong Zhao, Wenyong Fei, Shaobai Wang

PMC · DOI: 10.3390/bioengineering12040338 · Bioengineering · 2025-03-24

## TL;DR

Surgical robots improve tunnel and graft angles in ACL reconstruction, potentially reducing complications and improving outcomes.

## Contribution

Demonstrates that surgical robots enhance precision in tunnel angle and graft bending during ACL reconstruction.

## Key findings

- The femoral tunnel angle was significantly larger in the robot group.
- The graft bending angle was significantly less acute in the robot group.
- The posterior wall distance was significantly greater in the robot group.

## Abstract

The anatomic characteristics of the graft and tunnel, i.e., the tunnel position, angle, length, and the graft bending angle, influence knee joint stability and postoperative functional recovery. The purpose of this study was to evaluate the tunnel position, length and angle, as well as graft bending angle after ACL reconstruction assisted by a surgical robot. A total of 70 patients were randomized into two groups: the surgical robot group (robot group, n = 35) and the traditional handheld locator group (control group, n = 35). Postoperative computed tomography (CT) was employed to assess the positions and lengths of the tunnels, as well as the tunnel angle and the graft bending angle. Additionally, the posterior wall distance was measured by determining the minimum vertical distance from the long axis of the tunnel to the posterior wall region. There were no significant differences between the two groups in the mean position or length of the femoral and tibial tunnel (p > 0.05). However, the femoral tunnel angle was significantly larger in the robot group compared to the handheld locator group (p = 0.012). The graft bending angle was significantly less acute in the robot group than in the control group (p = 0.008). Additionally, the posterior wall distance was significantly greater in the robot group compared to the control group (p < 0.001). The results suggest that surgical robot-assisted ACL reconstruction enhances safety in the inclination of the tunnel and graft, helping to avoid potential biomechanical issues such as the wiper effect and the bungee effect, which may lead to tunnel widening and surgical failure.

## Full-text entities

- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12025089/full.md

## Figures

7 figures with captions in the complete paper: https://tomesphere.com/paper/PMC12025089/full.md

## References

45 references — full list in the complete paper: https://tomesphere.com/paper/PMC12025089/full.md

---
Source: https://tomesphere.com/paper/PMC12025089