# Evaluation of Aggregate Oral Fluids for African Swine Fever Real–Time PCR Diagnostics Using Samples Collected on Romanian Farms with an Active Outbreak

**Authors:** Chungwon Joseph Chung, Marta D. Remmenga, Sarah R. Mielke, Matthew Branan, Andrei Daniel Mihalca, Oana-Maria Balmos, David Adrian Balaban Oglan, Alexandru Supeanu, Attila Farkas

PMC · DOI: 10.1155/2024/9142883 · Transboundary and Emerging Diseases · 2024-08-13

## TL;DR

This study evaluates the use of pig oral fluids for detecting African swine fever virus using real-time PCR, finding it as effective as blood testing during outbreaks.

## Contribution

The study demonstrates that aggregate oral fluids can be a reliable supplementary diagnostic sample for African swine fever.

## Key findings

- Real-time PCR using aggregate oral fluids showed no statistical difference in sensitivity compared to blood testing.
- Aggregate oral fluid samples from the U.S. had no false positives, indicating high diagnostic specificity.
- The study suggests cautious use of oral fluids as a supplementary sample type until further validation.

## Abstract

African swine fever (ASF), caused by African swine fever virus (ASFv), is a highly contagious disease of domestic and wild pigs with a mortality rate that can reach 100%. Continuous spread of the virus into ASF-free regions, including the Caribbean island of Hispaniola in 2021, is causing socioeconomic burdens and presents a threat to food security. Pork-producing countries, including the United States and Canada, are urgently looking for efficient tools for early detection to reduce spread of the virus in the event of an outbreak. Previous experimental infection studies evaluated the utility of aggregate porcine oral fluids (OFs) as a sample type with a highly sensitive ASFv real-time PCR for individual blood and tissue-based diagnosis. In this study, real-time PCR with porcine OFs was further evaluated to better understand diagnostic performance using samples from three Romanian farms with an ongoing ASF outbreak. In this limited dataset using a Bayesian latent class model, no statistical difference in diagnostic sensitivity was found between the real-time PCR using aggregate OFs and the process of determining pen disease status by testing individual blood samples collected from a subset of pigs from the same pen. Known negative aggregate OF samples from pigs in the United States had no occurrences of false positives, suggesting reliable diagnostic specificity of the sample matrix used for this study. Until results are produced from further studies with sufficient sample size, aggregate OF testing using real-time PCR could cautiously be used as a supplementary sample type for ASF diagnosis alongside currently approved sample types, including blood and lymphoid tissues.

## Linked entities

- **Diseases:** African swine fever (MONDO:0025377)

## Full-text entities

- **Diseases:** ASF (MESH:D000357), infection (MESH:D007239)
- **Species:** Sus scrofa (pig, species) [taxon 9823], African swine fever virus (no rank) [taxon 10497]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC12017018/full.md

## Figures

1 figure with captions in the complete paper: https://tomesphere.com/paper/PMC12017018/full.md

## References

31 references — full list in the complete paper: https://tomesphere.com/paper/PMC12017018/full.md

---
Source: https://tomesphere.com/paper/PMC12017018