# Successful percutaneous closure of an iatrogenic right ventricular perforation utilizing an Angio-Seal device: a case report

**Authors:** Abdulrahman Arabi, Amr A Ashour, Mawahib El Hassan, Bassam Shoman, Abdulwahid Al Mulla

PMC · DOI: 10.1093/ehjcr/ytaf128 · European Heart Journal. Case Reports · 2025-03-14

## TL;DR

A patient with a heart puncture during a medical procedure was successfully treated using a less invasive device, avoiding major surgery.

## Contribution

Demonstrates successful use of an Angio-Seal device for percutaneous closure of a right ventricular perforation.

## Key findings

- Angio-Seal device effectively closed a right ventricular perforation without complications.
- The patient recovered well with no worsening of pericardial effusion on follow-up imaging.
- Percutaneous closure may be a viable alternative to emergency open cardiac surgery in high-risk patients.

## Abstract

Pericardiocentesis, a procedure with potential life-saving implications, can lead to complications such as cardiac perforation. Emergency open cardiac surgery, the conventional approach for addressing iatrogenic or traumatic cardiac perforations, is associated with unfavourable outcomes in high-risk patients. This report explores a case of accidental iatrogenic right ventricular (RV) puncture, which was effectively managed using a percutaneous closure device.

A 42-year-old male was hospitalized due to a persistent cough, dyspnoea, and fever, raising suspicion of tuberculosis. He was found to have a large pericardial effusion with signs of impending cardiac tamponade. During an attempted pericardiocentesis at an outside facility, his right ventricle was inadvertently perforated by a catheter. He was transferred to a specialized hospital to be assessed by a cardiac surgeon, where the heart team performed a percutaneous closure of the perforation using an Angio-Seal device, which was successful. A subsequent pericardiectomy was performed to address the effusion and confirm the absence of tuberculosis or malignancy. The patient recovered well, and follow-up imaging showed no worsening of the pericardial effusion. He was discharged in stable condition.

Pericardiocentesis, while crucial for treating large pericardial effusions, carries a small risk of complications such as ventricular perforation. Although surgery is a cornerstone in management, the Angio-Seal device has been used successfully in some cases to repair these tears. In this case, an Angio-Seal device effectively closed a RV rupture, with no further complication seen in follow-up exams. This suggests Angio-Seal as a potentially useful, less invasive option for treating such complications.

## Linked entities

- **Diseases:** tuberculosis (MONDO:0018076), cardiac tamponade (MONDO:0001297), pericardial effusion (MONDO:0001370)

## Full-text entities

- **Diseases:** cardiac perforation (MESH:D057112), RV rupture (MESH:D012421), fever (MESH:D005334), tuberculosis (MESH:D014376), right ventricular perforation (MESH:D018497), ventricular perforation (MESH:D018658), malignancy (MESH:D009369), tears (MESH:D012167), pericardial effusion (MESH:D010490), cough (MESH:D003371), cardiac tamponade (MESH:D002305), effusion (MESH:D000080324)
- **Chemicals:** Angio-Seal (-)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11971473/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11971473/full.md

## References

7 references — full list in the complete paper: https://tomesphere.com/paper/PMC11971473/full.md

---
Source: https://tomesphere.com/paper/PMC11971473