# Expandable grid, a simple, readily available and precise technique for intraoperative stereotactic real-time imaging

**Authors:** Dirar Aldabek, Andreas Hodul, François Alesch

PMC · DOI: 10.1007/s00701-025-06505-8 · Acta Neurochirurgica · 2025-04-02

## TL;DR

This paper introduces a simple and accurate method for real-time imaging during stereotactic surgery using fluoroscopy and a grid system.

## Contribution

The novel contribution is a cost-effective and precise intraoperative stereotactic technique using fluoroscopy and a printed grid for coordinate validation.

## Key findings

- The technique achieved sub-millimeter accuracy in validating stereotactic coordinates.
- It was validated using both phantom and real intraoperative imaging with consistent results.
- The method is applicable to multiple stereotactic systems and provides immediate coordinate feedback.

## Abstract

Pre- and postoperative imaging constitutes a firm brick in planning and steering accurate stereotactic procedures. The availability of intraoperative control measures, e.g., CT, MRI, and microelectrode recording (MER), is often limited to a minority of centers. Our approach utilizes fluoroscopy for target planning and coordinates validation as control.

This technique was primarily conceived for the RM (Riechert Mundinger) stereotactic system, but it also applies to the ZD (Zamorano—Dujovny) system. In the present study, we shifted the zero of the Z-value (axis of the patient) to + 60 mm. This corresponds to the center of the Angio/X-ray localizing plates. By assigning a radiopaque marker to the center of each plate, aligning these centers produced orthogonal and non-distorted stereotactic space. In this space, the magnification variable matters to us the most. Using available viewer software, we printed a millimetric grid on translucent foils with the corresponding magnification factor, which can easily be superimposed on the fluoroscopic image. This allows the precise validation of the coordinates of points of interest, including typical stereotactic landmarks. This technique can be used in both views, AP and lateral.

We have validated this technique under non-clinical (phantom) conditions and with intraoperative images obtained during routine stereotactic procedures. The latter were acquired using our classical stereotactic fixedly-mounted X-ray system. We found identical results, with an accuracy margin of error lower than 1 mm.

This simple geometrical adaptation proved to be an accurate, accessible, mobile, and manageable technique providing immediate access to stereotactic coordinates during surgery. The accuracy proved to be non-inferior to other more complex and time-consuming imaging modalities.

## Full-text entities

- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11965197/full.md

## Figures

10 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11965197/full.md

## References

1 references — full list in the complete paper: https://tomesphere.com/paper/PMC11965197/full.md

---