# Catheter-Associated Urinary Tract Infection in Critically Ill Patients: A Comparative Evaluation Between Latex Urinary Catheter and Metal Alloy-Coated Urinary Catheter

**Authors:** Farah Adibah Mohamed Hassan, Aliza Mohamad Yusof, Saw Kian Cheah, Mohd Khazrul Nizar Abd Kader, Wan Rahiza Wan Mat, Mohammad Nizam Mokhtar

PMC · DOI: 10.7759/cureus.79689 · 2025-02-26

## TL;DR

This study compared latex and metal alloy-coated urinary catheters in ICU patients and found no significant difference in infection rates.

## Contribution

The study provides new evidence on the comparative effectiveness of metal alloy-coated versus latex urinary catheters in preventing CAUTI in critically ill patients.

## Key findings

- One CAUTI case occurred in the latex catheter group, while none occurred in the metal alloy group.
- There was no statistically significant difference in CAUTI incidence between the two catheter types.
- The study found no benefit of metal alloy-coated catheters over latex ones in reducing CAUTI in short-term ICU use.

## Abstract

Background and objective

Catheter-associated urinary tract infection (CAUTI) accounts for 9% of all hospital-acquired infections (HAI). This study aimed to assess the incidence of CAUTI among patients with two different types of urinary catheters: the latex urinary catheter and the latex-coated metal alloy urinary catheter, used in the ICU setting.

Methods

This was a randomized, prospective, single-blinded study involving 76 ICU patients requiring catheterization and admitted to the ICU for more than 48 hours. Patients were allocated to the metal alloy catheter group and latex catheter group, with a randomization ratio of 1:1. CAUTI incidence was assessed at study entry, after 48 hours in the ICU, day seven in ICU, as well as any signs or symptoms of CAUTI detected during ICU stay. For statistical analysis, categorical data were compared using the chi-square or Fischer's exact test, and clinical outcomes were compared using the t-test.

Results:

A total of 76 patients were initially recruited for the study; however, six of them dropped out, leaving 70 patients for the final assessment. The mean age of the cohort was 48.6 ± 19.2 years and a majority of them were of Malay race (70.0%) and male (61.4%). The mean Acute Physiology and Chronic Health Evaluation II (APACHE II) and Sequential Organ Failure Assessment (SOFA) scores were 13.2 ± 4.0 and 6.1 ± 2.0 respectively. The mean ICU length of stay was 6 ± 1.58 days and the mean day of catheterization was 6 ± 1.54 days. One incidence of CAUTI was seen in the latex catheter group while no incidence was observed in the metal alloy group.

Conclusions

Based on our findings, there is no statistically significant difference in the incidence of CAUTI between the latex urinary catheter and the metal alloy urinary catheter groups for short-term catheterization in critically ill patients.

## Full-text entities

- **Diseases:** HAI (MESH:D003428), acquired infections (MESH:D017714), Critically Ill (MESH:D016638), Failure (MESH:D051437), CAUTI (MESH:D014552)
- **Chemicals:** Metal Alloy (-)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

3 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11952082/full.md

---
Source: https://tomesphere.com/paper/PMC11952082