# What Mistakes Can Be Made When Performing the Electrical Cardioversion Procedure?—Analysis of Emergency Medical Team Performance during the Championships in Emergency Medicine

**Authors:** Michał Ćwiertnia, Mieczysław Dutka, Piotr Białoń, Michał Szlagor, Arkadiusz Stasicki, Monika Mikulska, Maciej B. Hajduga, Rafał Bobiński, Marek Kawecki, Tomasz Ilczak

PMC · DOI: 10.3390/healthcare12171724 · Healthcare · 2024-08-29

## TL;DR

This study analyzed how emergency medical teams performed electrical cardioversion during simulated scenarios and found that mistakes increased with each subsequent shock.

## Contribution

The study highlights the decline in correct procedure execution during repeated shocks in electrical cardioversion by emergency teams.

## Key findings

- Most teams correctly decided to perform electrical cardioversion in both 2015 and 2019.
- The percentage of correct actions, such as sync mode and energy use, decreased significantly with each subsequent shock.
- Teams generally performed shocks safely, but sync mode errors increased over time.

## Abstract

Background: Medical personnel carrying out electrical cardioversion (EC) procedures must remember to have the R-wave sync mode switched on, use the correct energy and maintain personal safety. The defibrillators used by medical response teams most often switch out of cardioversion mode once a shock is delivered. Therefore, this mode must be switched on again before subsequent shocks are delivered. The main aim of the study was to assess the ability of emergency medical teams participating in emergency medicine championships to perform EC. Methods: The research was a retrospective observational study and was based on an analysis of the evaluation sheets from two tasks simulating the management of a patient with unstable tachycardia conducted during the International Winter Emergency Medicine Championships. Three-person teams consisting of paramedics and representing the Polish emergency services were included in the study. The team representing the championship organiser and the few foreign teams participating in the competition were excluded from the study. Results: The decision to conduct EC was taken by 36 teams (83.72%) in 2015 and 27 teams (87.10%) in 2019. In both editions of the championships, during consecutive shocks, the percentage of actions performed correctly decreased significantly—switching on synchronisation mode in 2015 (94.4%, 83.33%, 72.22%) and in 2019 (100%, 88.89%, 81.48%); correct energies in 2015 (91.67%, 80.56%, 77.78%) and in 2019 (92.59%, 85.19%, 81.48%); shocks in a safe manner in 2015 (94.44%, 94.44%, 91.67%) and in 2019 (100%, 96.30%, 96.30%). Conclusions: Teams participating in the assessed tasks in a significant majority of cases correctly qualified the patient for EC, and correctly carried out the actions required for this procedure. It is of particular note that with every subsequent shock, the percentage of shocks carried out without the sync mode increased significantly.

## Full-text entities

- **Diseases:** tachycardia (MESH:D013610)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11394996/full.md

## Figures

3 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11394996/full.md

## References

34 references — full list in the complete paper: https://tomesphere.com/paper/PMC11394996/full.md

---
Source: https://tomesphere.com/paper/PMC11394996