This study analyzed eye measurements in children with cataracts to improve surgical outcomes and lens placement decisions.

## Contribution

The study provides new insights into correlations between ocular biometric parameters and IOL placement in pediatric cataract patients.

## Key findings

- Older children with larger corneal diameters and longer axial lengths were more likely to receive in-the-bag IOL implantation.
- Over 95% of the study population had a corneal diameter of 10 mm or larger.
- Femtosecond laser use was found to be feasible and safe for children aged one year and older.

## Abstract

Objectives: This study aims to provide a comprehensive analysis of ocular biometric parameters in pediatric patients with cataracts to optimize surgical outcomes. By evaluating various biometric data, we seek to enhance the decision-making process for intraocular lens (IOL) placement, particularly with advanced technologies like femtosecond lasers. Methods: This retrospective comparative study included pediatric patients with cataracts who underwent ocular biometric measurements and cataract extraction with anterior vitrectomy at the Medical University of Vienna between January 2019 and December 2021. Parameters measured included corneal diameter (CD), axial length (AL), corneal thickness (CT) and flat and steep keratometry (Kf and Ks). The study explored the correlations between these parameters and IOL placement. Results: A total of 136 eyes from 68 pediatric patients were included in the study. Significant positive correlations were found between corneal diameter, age and AL. The mean CD was 11.4 mm, mean AL was 19.5 mm, CT was 581.2 ± 51.8 µm, Kf was 7.76 ± 0.55 mm and Ks 7.41 ± 0.59 mm, respectively. Older pediatric patients with larger corneal diameters and longer ALs were more likely to receive in-the-bag IOL implantation. Conversely, younger patients often required alternative IOL placements or remained aphakic. Our data indicated that over 95% of the study population and all patients aged one year and older had a corneal diameter of 10 mm or larger. Conclusions: Detailed ocular biometric analysis is crucial for optimizing both surgical outcomes and postoperative care in pediatric cataract patients. The positive correlations between CD, age and AL underline the importance of individualized surgical planning tailored to each patient’s unique anatomical features. Additionally, our findings suggest that the use of a femtosecond laser is both feasible and safe for pediatric patients aged one year and older, potentially offering enhanced surgical precision and improved outcomes.

## Linked entities

- **Species:** Homo sapiens (taxon 9606)

## Full-text entities

- **Diseases:** Cataract (MESH:D002386)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

5 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11355302/full.md

---
Source: https://tomesphere.com/paper/PMC11355302