## TL;DR

This study found that DOACs are as safe and effective as warfarin for high-risk patients after a WATCHMAN procedure.

## Contribution

The study provides new evidence on the safety and efficacy of DOACs compared to warfarin after left atrial appendage closure.

## Key findings

- The primary composite outcome was similar between DOAC and warfarin groups through 7 and 45 days.
- Device-related thrombus and significant peri-device flow were rare (<0.5%).
- DOACs are potentially safe and effective following the WATCHMAN procedure.

## Abstract

In the pivotal WATCHMAN trials, warfarin was used exclusively for postprocedural anticoagulation following left atrial appendage closure. We sought to investigate the safety and efficacy of direct oral anticoagulants (DOACs) in high-risk patients with atrial fibrillation who underwent left atrial appendage closure with WATCHMAN.

This was a retrospective study of 318 patients who underwent the WATCHMAN procedure in a tertiary referral center (June 2016-September 2020). We compared the outcomes of patients who were discharged on DOACs versus warfarin after the WATCHMAN procedure. The primary outcome was the composite of any bleeding, thromboembolism, or cardiovascular death through 7 ​days and 45 ​days after the procedure.

The final analysis included 301 patients, of whom 82.4% (248/301) were discharged on DOACs and 17.6% (53/301) were discharged on warfarin. The mean CHA2DS2-VASc and HAS-BLED scores were 4.9 ​± ​1.6 and 2.9 ​± ​0.9, respectively. The primary composite outcome was similar between the DOAC and warfarin groups through 7 ​days (3.2% vs 5.6%; adjusted odds ratio [OR], 0.65; 95% confidence interval [CI], 0.13-3.17; P ​= ​.59) and 45 days after procedure (10.1% vs 11.3%; adjusted OR, 1.18; 95% CI, 0.41-3.45; P ​= ​.76). Major bleeding (5.2% vs 9.5%; P ​= ​.34) and all-cause readmission (12.5% vs 16.9%; P ​= ​.85) at 45 ​days were comparable between the DOAC and warfarin groups. The overall incidence of device-related thrombus and significant peri-device flow at 45 ​days were low (<0.5%).

In high-risk patients with atrial fibrillation, the primary composite outcome of any bleeding, thromboembolism, or cardiovascular death through 7 ​days and 45 ​days following WATCHMAN implantation was similar in patients receiving DOACs versus warfarin.

•The composite of bleeding, thromboembolism, or cardiovascular death was similar for DOAC vs warfarin after WATCHMAN.•Overall, device-related thrombus and peri-device flow >5 ​mm were rare (<0.5%).•DOACs are potentially safe and effective following WATCHMAN procedure.

The composite of bleeding, thromboembolism, or cardiovascular death was similar for DOAC vs warfarin after WATCHMAN.

Overall, device-related thrombus and peri-device flow >5 ​mm were rare (<0.5%).

DOACs are potentially safe and effective following WATCHMAN procedure.

## Linked entities

- **Chemicals:** warfarin (PubChem CID 54678486)
- **Diseases:** atrial fibrillation (MONDO:0004981)

## Full-text entities

- **Diseases:** thrombus (MESH:D013927), thromboembolism (MESH:D013923), bleeding (MESH:D006470), atrial fibrillation (MESH:D001281), cardiovascular death (MESH:D002318)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11307383/full.md

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11307383/full.md

## References

22 references — full list in the complete paper: https://tomesphere.com/paper/PMC11307383/full.md

---
Source: https://tomesphere.com/paper/PMC11307383