Application of reference air kerma alert levels for pediatric fluoroscopic examinations

Abstract
Genes, proteins, chemicals, diseases, species, mutations and cell lines named across the full text — each resolved to its canonical identifier and authoritative record.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsRadiation Dose and Imaging · Digital Imaging in Medicine
Current Authors:
Elanchezhian Somasundaram, Samuel Loren Brady, and Keith Jerel Strauss
Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati OH
Department of Radiology, University of Cincinnati School of Medicine, Cincinnati, OH
Institution of Origin:
Cincinnati Children's Hospital Medical Center
MLC 5031, 3333 Burnet Avenue
Cincinnati, OH 45229‐3026
Corresponding Author:
Samuel L. Brady, MS PhD, FAAPM
Department of Radiology
Cincinnati Children's Hospital Medical Center
MLC 5031, 3333 Burnet Avenue
Cincinnati, OH 45229‐3026
Original Citation
Somasundaram E, Brady SL, Strauss KJ, Application of reference air kerma alert levels for pediatric fluoroscopic examinations J Appl Clin Med Phys. 2022;e13721.
Author Original Contribution Statement:
All three authors have:
- Made substantial contributions to the conception and design of the manuscript,
- Actively acquired, analyzed, and interpreted data of the manuscript,
- Drafted and/or revised manuscript for intellectual content,
- Approved the final submitted manuscript, and
- Agree to be accountable for all aspects of the manuscript.
Disclosures:
No COI for E.S., S.L.B., nor K.J.S. No funding supported this project.
ERRATUM: Application of reference air kerma alert levels for pediatric fluoroscopic examinations
Equation ( 5 ) had a typographical error; the equation should read:
where, c^ is the intercept value of the linear dose fit and may be calculated for each institution based on the average *RAK_avg_
- for their average size or age patient (xavg), m was the mean slope of the upper prediction boundary, and sα was the logarithmic ratio of the dose at trigger level α to the mean dose level at a given patient size or age x. Coefficients sα were updated in Table 3 based on the newly modified Equation ( 5 ). A sample calculation is provided to illustrate the application of the empirical model in our previous study with the updated Equation ( 5 ). The calculation illustrates the application of the empirical model of this study to model RAK alert levels for a different facility. Assume an adult facility calculates the average RAK for a sampling of adult patients with 25 cm anteroposterior thickness to be 20 mGy for GI studies. The unique intercept value for the adult facility, which appropriately scales the empirical model of this study, is calculated with Equation (6) and coefficient data from Table 3:
The RAK alert level based on the 98^th^ upper prediction level can then be calculated for a 2 year‐old toddler with a 12 cm thick anteroposterior projection and for the adult patient with a 25 cm anteroposterior thickness using Equation (5) and coefficient data from Table 3:
