# Use of echocardiography in percutaneous closure of patent ductus arteriosus at the Instituto Nacional de Salud del Niño, San Borja, Lima - Peru

**Authors:** Alex I. Catalán, Karen Condori, Mónica Medina, Stella Lucena, David Montoya, Ricardo Gálvez-Arévalo

PMC · DOI: 10.47487/apcyccv.v5i2.350 · 2024-06-24

## TL;DR

This study compares using echocardiography versus fluoroscopy for closing patent ductus arteriosus in children, finding similar success rates but fewer risks with echocardiography.

## Contribution

Demonstrates that echocardiography can replace fluoroscopy in PDA closure with equivalent success and reduced radiation exposure.

## Key findings

- PDA closure success rate was 100% with echocardiography and 98% with fluoroscopy.
- Echocardiography reduced fluoroscopy time and radiation dose significantly.
- Echocardiography avoids femoral artery access and contrast use.

## Abstract

Percutaneous occlusion of patent ductus arteriosus (PDA) has classically been performed entirely by fluoroscopy, however in recent years, transthoracic echocardiography (TE) has been used as an aid to fluoroscopy or entirely by echocardiography, which avoids access of femoral artery, use of contrast and decrease in time and dose of radiation exposure. The objective of this study was to evaluate the success rate with the use of TE in percutaneous PDA closure.

Descriptive, comparative, retrospective study between patients in whom PDA closure was performed with fluoroscopy plus angiography (group 1) and fluoroscopy plus ET (group 2), between January 2018 and December 2022. The data were obtained from the clinical history electronic and procedure report.

One hundred eight patients were analyzed, fluoroscopy group (n: 57) and TE (n: 51). The success rate in PDA occlusion using TE was 100% and 98% for the fluoroscopy group, with no statistically significant difference The average age of group 2 was 2.9 years, while the average age of group 1 was 5 years (p=0.001), the average fluoroscopy time in group 1 was 16.9 min and 4.71 min in group 2 (p < 0.001); the fluoroscopy dose in group 1 was 68.98 mGy and 5.17 mGy in group 2 (p<0.001). Krichenko, but without significant difference in both groups.

The success rate of percutaneous PDA closure using echocardiography and fluoroscopy is appropiate, with a success rate similar to the classic technique. In addition, it makes it possible to reduce the dose and time of fluoroscopy, avoid the use of contrast, and access the femoral artery.

## Linked entities

- **Diseases:** patent ductus arteriosus (MONDO:0011827)

## Full-text entities

- **Diseases:** PDA (MESH:D004374)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11247972/full.md

---
Source: https://tomesphere.com/paper/PMC11247972