# Artificial Neural Network Prediction of Compliance Coefficients for Composite Shear Keys of Built-Up Timber Beams

**Authors:** Irene A. Ladnykh, Nabi Ibadov, Hubert Anysz

PMC · DOI: 10.3390/ma17133246 · Materials · 2024-07-02

## TL;DR

This paper uses artificial neural networks to predict compliance coefficients for composite shear keys in timber beams, improving design accuracy.

## Contribution

The authors compiled experimental data and proposed a new ANN architecture for predicting compliance coefficients.

## Key findings

- An artificial neural network was developed to predict compliance coefficients for composite shear keys.
- The mean absolute percentage error for predicted coefficients was 0.054% for kw and 0.052% for ki.
- The proposed method can be practically applied in designing timber beams with various shear keys.

## Abstract

This article explores the possibility of predicting the compliance coefficients for composite shear keys of built-up timber beams using artificial neural networks. The compliance coefficients determine the stresses and deflections of built-up timber beams. The article analyzes current theoretical methods for designing wooden built-up timber beams with shear keys and possible ways of applying them in modern construction. One of the design methods, based on the use of the compliance coefficients, is also discussed in detail. The novelty of this research is that the authors of the article collected, analysed, and combined data on the experimental values of the compliance coefficient for composite shear keys of built-up timber beams obtained by different researchers and published in other studies. For the first time, the authors of this article generated a table of input and output data for predicting compliance coefficients based on the analysis of the literature and collected data by the authors. As a result of this research, the article’s authors proposed an artificial neural network (ANN) architecture and determined the mean absolute percentage error for the compliance coefficients kw and ki, which are equal to 0.054% and 0.052%, respectively. The proposed architecture can be used for practical application in designing built-up timber beams using various composite shear keys.

## Full-text entities

- **Diseases:** injury to people or property (MESH:C000719191), fire (MESH:D000092422)
- **Chemicals:** carbon (MESH:D002244), steel (MESH:D013232), FRP materials (-), epoxy (MESH:D004853)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11243453/full.md

## Figures

10 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11243453/full.md

## References

44 references — full list in the complete paper: https://tomesphere.com/paper/PMC11243453/full.md

---
Source: https://tomesphere.com/paper/PMC11243453