# Effects of Wearing Personal Protective Equipment on Serum Cortisol Levels and Physiological Variables in Healthcare Workers: A Randomised Controlled Trial in a Simulated Pandemic Environment

**Authors:** Pradip Barde, Vinay Chitturi, Gaurav Sharma, Naresh Parmar, Rajesh Kathrotia, Deepak Parchwani, Vivek K Sharma

PMC · DOI: 10.7759/cureus.61687 · Cureus · 2024-06-04

## TL;DR

Wearing full-body PPE increases stress hormones and affects health metrics in healthcare workers during simulated pandemic conditions.

## Contribution

This study is the first to show how full-body PPE impacts cortisol and physiological stress in a simulated pandemic setting.

## Key findings

- Serum cortisol levels significantly increased in participants wearing full-body PPE.
- Heart rate variability data showed increased sympathetic nervous system activity in the PPE group.
- Physiological variables like heart rate and temperature were affected by PPE use.

## Abstract

Introduction: The COVID-19 pandemic has necessitated the widespread use of personal protective equipment (PPE), particularly in high-risk environments. Full-body PPE is favoured for its comprehensive protection against the virus but poses challenges to the body's thermoregulatory system as it inhibits air exchange. This randomised trial was undertaken to investigate the effects of wearing a commonly used gown-type full-body PPE kit in a simulated environment.

Methods: Initially, 65 healthy males were recruited and randomly divided into two groups: a study group wearing a full-body PPE kit (gown-type, full-body PPE kit with trousers, a gown-type shirt with a hood, a shoe cover, an N95 face mask, and an optional face shield) and a control group without PPE. They remained seated for three hours while wearing the PPE kit. Room conditions mimicked non-air-conditioned hospital scenarios, with temperature and humidity recorded and ventilation provided through open doors and windows, along with ceiling fan cooling. Activities with minimal physical exertion were allowed, and access to the toilet was kept to a minimum. Subjects underwent assessments of heart rate, respiratory rate, temperature, blood pressure, heart rate variability (HRV), and blood samples for serum cortisol before donning the PPE kit and entering a simulated ICU/WARD environment and after doffing.

Results: A total of 60 participants completed the study (30 in each group). Compared to the controls, serum cortisol levels significantly increased in the PPE groups, and HRV data indicated increased sympathetic activity in the PPE group.

Conclusion: Wearing a full-body PPE kit (gown-type upper garment with trousers) was found to have a significant impact on cortisol levels and physiological variables in a simulated environment. This suggests that in situations like the COVID-19 pandemic that warrant the use of such PPE kits, appropriate measures should be taken to provide better thermal stability for maintaining the well-being of healthcare workers.

## Linked entities

- **Diseases:** COVID-19 (MONDO:0100096)

## Full-text entities

- **Diseases:** COVID-19 (MESH:D000086382)
- **Chemicals:** Cortisol (MESH:D006854)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11223943/full.md

## Figures

3 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11223943/full.md

## References

24 references — full list in the complete paper: https://tomesphere.com/paper/PMC11223943/full.md

---
Source: https://tomesphere.com/paper/PMC11223943