# Intraoperative variability of corneal epithelium thickness in photorefractive keratectomy

**Authors:** Dana Barequet, Eliya Levinger, Amir Rosenblatt, Samuel Levinger, Irina S. Barequet

PMC · DOI: 10.1007/s10792-024-03154-1 · International Ophthalmology · 2024-06-25

## TL;DR

This study found significant variability in corneal epithelium thickness during alcohol-assisted PRK surgery, which could affect surgical outcomes.

## Contribution

The study introduces new insights into intraoperative epithelial thickness variability in PRK and its potential impact on surgical planning.

## Key findings

- Central corneal epithelium thickness varied widely, with 55% of eyes outside the 40-60µm range.
- Epithelial thickness was significantly higher in the second operated eye compared to the first.
- Contact lens use was associated with epithelial thickness, but age, gender, and refractive errors were not.

## Abstract

To evaluate the intraoperative central corneal epithelial thickness (ET) as measured by optical coherence pachymetry (OCP) in myopic eyes undergoing alcohol-assisted photorefractive keratectomy (PRK).

A retrospective review of patients who underwent alcohol-assisted PRK was performed. Data were abstracted on age, gender, contact lens (CL) wear, preoperative refractive errors, keratometry, topographic and ultrasonic pachymetry, and intraoperative OCP measurements before and after epithelium removal. The central ET was calculated by subtracting OCP measurement after epithelium removal from the OCP measurement prior to epithelium removal.

The study comprised of 162 consecutive eyes from 81 patients. Mean age was 26.73 ± 6.47 years, 50.6% were males. CL was used in 92 eyes (56.8%). The mean sphere and spherical equivalent were −3.60 ± 1.84 D and −3.26 ± 1.85D, respectively. The mean intraoperative ET was 58.22 ± 17.53 µm (range, 15–121µm). Fifty-five percent of the eyes had an ET measurement above or below the range of 40-60µm. ET was significantly higher in the second operated eye compared to the first operated eye (p = 0.006), and an association was found to CL-wear (p = 0.03). There was no significant difference in thickness between genders (p = 0.62), and no correlation to patient age (p = 0.45, rp = 0.06), refractive errors (p > 0.30,rp=−0.07–0.08), nor keratometry(p > 0.80, rp=−0.01− (−0.02)).

The intraoperative assessment of ET in alcohol-assisted PRK showed a high variability of the central corneal epithelium, with a significant difference between the first and second operated eyes. This difference may have implications when the epithelium is not included in the surgical planning in surface ablation.

## Full-text entities

- **Diseases:** CL-wear (MESH:D007905)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11199205/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11199205/full.md

## References

2 references — full list in the complete paper: https://tomesphere.com/paper/PMC11199205/full.md

---
Source: https://tomesphere.com/paper/PMC11199205