# Cryoablation Utilizing the KODEX-EPD Mapping System Versus Conventional Cryoballoon Ablation in the Management of Patients With Atrial Fibrillation: A Literature Review and Meta-Analysis

**Authors:** Christopher R Meretsky, Vaishvik K Patel, Arshia Mahmoodi, Anthony T Schiuma

PMC · DOI: 10.7759/cureus.59407 · Cureus · 2024-04-30

## TL;DR

This study compares two cryoablation methods for treating atrial fibrillation and finds that using the KODEX-EPD mapping system reduces contrast use and recurrence rates without compromising safety or effectiveness.

## Contribution

The study introduces the KODEX-EPD mapping system as a novel improvement in cryoablation for atrial fibrillation.

## Key findings

- Cryoablation with the KODEX-EPD system significantly lowers recurrence rates compared to conventional methods.
- The system reduces the volume of contrast medium used during the procedure.
- Both methods show similar procedural duration, safety, and efficacy.

## Abstract

Atrial fibrillation (AF) is the most commonly encountered cardiac arrhythmia globally. AF is associated with different consequences, such as peripheral vascular embolism, stroke, dementia, heart failure, and death. Catheter ablation (CA) has become a reliable therapeutic option for symptomatic AF. Utilizing mapping systems in conducting cryoablation is supposed to improve pulmonary vein isolation (PVI) durability and overall treatment success rate. We performed a review of relevant articles. We formulated a search strategy as follows: (atrial fibrillation AND ("cryoballoon ablation" OR cryoablation) AND (KODEX-EPD AND KODEX OR mapping). Data were collected from Web of Science, PubMed, Cochrane Library, and SCOPUS databases. We assessed the efficacy, procedural characteristics, and safety of cryoablation using the KODEX-EPD mapping system versus conventional cryoablation. We demonstrated the superiority of cryoablation guided by the KODEX-EPD system as it was associated with a significantly lower recurrence rate after the procedure (RR = 0.61, P = 0.03). Furthermore, it allowed a significant reduction in the volume of contrast medium used during the procedure (MD = -20.46, P = 0.04) when compared to the conventional cryoablation. We found no significant difference between both procedures in terms of successful cryoballoon-based PVI (P = 1.00), procedural duration (P = 0.95), procedural complications (P = 0.607), fluoroscopic time (P = 0.36), and fluoroscopic dose (P = 0.16). The use of the novel KODEX-EPD mapping system in the cryoablation procedure was associated with a significant reduction of the volume of contrast medium use and the recurrence rate compared with the conventional cryoablation while preserving similar efficacy, safety profile, and procedure time.

## Linked entities

- **Diseases:** atrial fibrillation (MONDO:0004981)

## Full-text entities

- **Diseases:** dementia (MESH:D003704), heart failure (MESH:D006333), cardiac arrhythmia (MESH:D001145), peripheral vascular embolism (MESH:D016491), AF (MESH:D001281), death (MESH:D003643), stroke (MESH:D020521)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC11140424/full.md

## Figures

8 figures with captions in the complete paper: https://tomesphere.com/paper/PMC11140424/full.md

## References

34 references — full list in the complete paper: https://tomesphere.com/paper/PMC11140424/full.md

---