# Discussion of hemodynamic optimization strategies and the canonical understanding of hemodynamics during biventricular mechanical support in cardiogenic shock: does the flow balance make the difference?

**Authors:** Nikolaos Patsalis, Julian Kreutz, Giorgos Chatzis, Carlo-Federico Fichera, Styliani Syntila, Maryana Choukeir, Sebastian Griewing, Bernhard Schieffer, Birgit Markus

PMC · DOI: 10.1007/s00392-024-02377-7 · Clinical Research in Cardiology · 2024-01-23

## TL;DR

This paper explores how adjusting flow rates of heart support devices can improve blood flow and organ perfusion in patients with severe heart failure.

## Contribution

The study introduces a new hemodynamic optimization protocol using biventricular mechanical circulatory support in cardiogenic shock patients.

## Key findings

- Higher Impella flow compared to VA-ECMO flow significantly increases cardiac output and organ perfusion.
- Systemic vascular resistance and renal resistive index decrease with increased Impella flow.
- Pulmonary artery catheterization is effective for hemodynamic monitoring during biventricular support.

## Abstract

Mechanical circulatory support (MCS) devices may stabilize patients with severe cardiogenic shock (CS) following myocardial infarction (MI). However, the canonical understanding of hemodynamics related to the determination of the native cardiac output (CO) does not explain or support the understanding of combined left and right MCS. To ensure the most optimal therapy control, the current principles of hemodynamic measurements during biventricular support should be re-evaluated.

Here we report a protocol of hemodynamic optimization strategy during biventricular MCS (VA-ECMO and left ventricular Impella) in a case series of 10 consecutive patients with severe cardiogenic shock complicating myocardial infarction. During the protocol, the flow rates of both devices were switched in opposing directions (+ / − 0.7 l/min) for specified times. To address the limitations of existing hemodynamic measurement strategies during biventricular support, different measurement techniques (thermodilution, Fick principle, mixed venous oxygen saturation) were performed by pulmonary artery catheterization. Additionally, Doppler ultrasound was performed to determine the renal resistive index (RRI) as an indicator of renal perfusion.

The comparison between condition 1 (ECMO flow > Impella flow) and condition 2 (Impella flow > VA-ECMO flow) revealed significant changes in hemodynamics. In detail, compared to condition 1, condition 2 results in a significant increase in cardiac output (3.86 ± 1.11 vs. 5.44 ± 1.13 l/min, p = 0.005) and cardiac index (2.04 ± 0.64 vs. 2.85 ± 0.69, p = 0.013), and mixed venous oxygen saturation (56.44 ± 6.97% vs. 62.02 ± 5.64% p = 0.049), whereas systemic vascular resistance decreased from 1618 ± 337 to 1086 ± 306 s*cm−5 (p = 0.002). Similarly, RRI decreased in condition 2 (0.662 ± 0.05 vs. 0.578 ± 0.06, p = 0.003).

To monitor and optimize MCS in CS, PA catheterization for hemodynamic measurement is applicable. Higher Impella flow is superior to higher VA-ECMO flow resulting in a more profound increase in CO with subsequent improvement of organ perfusion.

## Linked entities

- **Diseases:** cardiogenic shock (MONDO:0800175), myocardial infarction (MONDO:0005068)

## Full-text entities

- **Diseases:** CS (MESH:D012770), myocardial infarction (MESH:D009203), output (MESH:D002303)
- **Chemicals:** oxygen (MESH:D010100), Impella (-)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC10954998/full.md

## Figures

6 figures with captions in the complete paper: https://tomesphere.com/paper/PMC10954998/full.md

## References

28 references — full list in the complete paper: https://tomesphere.com/paper/PMC10954998/full.md

---
Source: https://tomesphere.com/paper/PMC10954998