Response to Nguyen et al.'s letter regarding “Anteriolateral versus anterior–posterior electrodes in external cardioversion of atrial fibrillation: A systematic review and meta‐analysis of clinical trials”
Karam R. Motawea, Abdulqadir J. Nashwan

Abstract
Genes, proteins, chemicals, diseases, species, mutations and cell lines named across the full text — each resolved to its canonical identifier and authoritative record.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsAtrial Fibrillation Management and Outcomes · Cardiac Arrhythmias and Treatments · Cardiac pacing and defibrillation studies
Dear Editor,
We would like to thank Nguyen et al. for engaging with our systematic review and meta‐analysis1 and for your critical observations.2 Regarding the omission of four studies, our inclusion criteria were rigorously followed, which led to the exclusion of studies that did not meet these predefined standards. Specifically, three of these studies were either not in English or inaccessible in full text, preventing their inclusion.3, 4 The fourth study focused primarily on a subgroup analysis of patients with obesity, which did not align with our broader inclusion criteria encompassing all patient demographics, not limited to specific conditions like obesity.5
Concerning the inclusion of a prospective study, it appears there was a misunderstanding about the nature of the study we included. The study in question was a prospective interventional study, effectively functioning as a non‐randomized clinical trial, which falls within our criteria of including both randomized and non‐randomized clinical trials.6 This inclusion aligns with our commitment to a comprehensive analysis of clinical trials relevant to our research question.
As for the issue of data extraction, particularly regarding the studies by Alp et al.7 and Botto et al.,8 our methodology adhered strictly to the principles of accurate data appraisal. The overall cardioversion rates utilized in our analysis were directly reflective of the outcomes post‐application of DC shock and high energy, consistent with the intentions of the original studies. We believe this approach maintains the integrity of our analysis and supports the validity of our findings.
We acknowledge the value of constructive critique and the importance of rigorous debate in advancing scientific understanding. As the field moves forward, especially with ongoing trials like NCT05511389, we anticipate further clarification on optimal practices, including electrode pad placement. Our study contributes to this ongoing dialogue, and we advocate for continued research that incorporates best practices alongside new interventions.
CONFLICT OF INTEREST STATEMENT
The authors declare no conflict of interest.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1Motawea KR , Mostafa MR , Aboelenein M , et al. Anteriolateral versus anterior‐posterior electrodes in external cardioversion of atrial fibrillation: a systematic review and meta‐analysis of clinical trials. Clin Cardiol. 2023;46(4):359‐375.36756856 10.1002/clc.23987 PMC 10106664 · doi ↗ · pubmed ↗
- 2Nguyen ST B‐CE , Mc Intyre WF . Anteriolateral versus anterior‐posterior electrodes in external cardioversion of atrial fibrillation: a systematic review and meta‐analysis of clinical trials, Clinical Cardiology, 2024;47(3):e 24249. 10.1002/clc.24249 38436483 PMC 10910448 · doi ↗ · pubmed ↗
- 3Brazdzionyte J , Babarskiene RM , Stanaitiene G . Anterior‐posterior versus anterior‐lateral electrode position for biphasic cardioversion of atrial fibrillation. Medicina. 2006;42(12):994‐998.17211107 · pubmed ↗
- 4Muñoz‐Martínez T , Castañeda‐Saiz A , Vinuesa‐Lozano C , et al. Estudio aleatorizado sobre la posición de electrodos en la cardioversión eléctrica electiva de la fibrilación auricular. Med Intensiva. 2010;34(4):225‐230.20036036 10.1016/j.medin.2009.10.004 · doi ↗ · pubmed ↗
- 5Voskoboinik A , Moskovitch J , Plunkett G , et al. Cardioversion of atrial fibrillation in obese patients: results from the Cardioversion‐BMI randomized controlled trial. J Cardiovasc Electrophysiol. 2019;30(2):155‐161.30375104 10.1111/jce.13786 · doi ↗ · pubmed ↗
- 6Kerber RE , Grayzel J , Hoyt R , Marcus M , Kennedy J . Transthoracic resistance in human defibrillation. Circulation. 1981;63(3):676‐682.7460251 10.1161/01.cir.63.3.676 · doi ↗ · pubmed ↗
- 7Alp NJ , Rahman S , Bell JA , Shahi M . Randomised comparison of antero‐lateral versus antero‐posterior paddle positions for DC cardioversion of persistent atrial fibrillation. Int J Cardiol. 2000;75(2‐3):211‐216.11077136 10.1016/s 0167-5273(00)00326-0 · doi ↗ · pubmed ↗
- 8Botto GL , Politi A , Bonini W , Broffoni T , Bonatti R . External cardioversion of atrial fibrillation: role of paddle position on technical efficacy and energy requirements. Heart. 1999;82(6):726‐730.10573502 10.1136/hrt.82.6.726PMC 1729223 · doi ↗ · pubmed ↗