## TL;DR

This study shows that using saline flush during OCT imaging in heart procedures is safe, effective, and better for kidney health.

## Contribution

The study evaluates saline flush efficacy in FD-OCT imaging and identifies predictors of high-quality images.

## Key findings

- 87% of OCT imaging runs achieved clinically acceptable image quality using saline flush.
- Intensive flushing improved image quality, especially in the left coronary artery.
- Saline flush was safe and reduced contrast media use, benefiting patients with kidney disease.

## Abstract

The increased amount of contrast media in frequency-domain optical coherence tomography (FD-OCT) imaging during percutaneous coronary intervention (PCI) has raised potential concerns regarding impairment of renal function.

This study aimed to evaluate the effectiveness of heparinized saline flush in FD-OCT-guided PCI and identify clinical factors contributing to optimal image quality.

We retrospectively collected 100 lesions from 90 consecutive patients, and a total of 200 pullbacks were analyzed for the initial and final evaluation in which saline was used as the flushing medium.

The study population had a mean age of 73, with 52% having chronic kidney disease (CKD). The median amount of contrast used was 28 ml, and no complications were observed associated with saline flush OCT. Imaging quality was then categorized as excellent, good, or unacceptable. Among the total runs, 87% demonstrated clinically acceptable image quality, with 66.5% classified as excellent images and 20.5% classified as good images. Independent predictors of excellent images included lumen area stenosis ≥ 70% (adjusted odds ratio [OR] 2.37, 95% confidence interval [CI] 1.02–5.47, P = 0.044), and the use of intensive flushing (adjusted OR 2.06, 95% CI 1.11–3.86, P = 0.023) defined as a deep engagement of guiding catheter (GC) or a selective insertion of guide extension catheter (GE). Intensive flushing was performed in 60% of the total pullbacks, and it was particularly effective in improving image quality in the left coronary artery (LCA).

The use of saline flush during FD-OCT imaging was safe and feasible, which had a benefit in renal protection with adequate imaging quality.

## Linked entities

- **Chemicals:** saline (PubChem CID 5234)
- **Diseases:** chronic kidney disease (MONDO:0005300), coronary artery disease (MONDO:0005010)

## Full-text entities

- **Diseases:** impairment of renal function (MESH:D007674), saline flush (MESH:D005483), CKD (MESH:D051436)
- **Chemicals:** saline (MESH:D012965)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC10920414/full.md

## Figures

4 figures with captions in the complete paper: https://tomesphere.com/paper/PMC10920414/full.md

## References

27 references — full list in the complete paper: https://tomesphere.com/paper/PMC10920414/full.md

---
Source: https://tomesphere.com/paper/PMC10920414