# Projection-Angle-Sensor-Assisted X-ray Computed Tomography for Cylindrical Lithium-Ion Batteries

**Authors:** Jiawei Dong, Lingling Ju, Quanyuan Jiang, Guangchao Geng

PMC · DOI: 10.3390/s24041102 · Sensors (Basel, Switzerland) · 2024-02-08

## TL;DR

This paper shows how using an angle sensor during X-ray scans improves image quality for lithium-ion battery analysis.

## Contribution

The study introduces angle sensors to reduce projection angle errors in XCT for better battery imaging.

## Key findings

- Projection angle errors cause noise and stripe artifacts in XCT images.
- Angle sensors on the rotary table improve image quality and reduce artifacts.
- Residual projection errors correlate with image quality degradation.

## Abstract

X-ray computed tomography (XCT) has become a powerful technique for studying lithium-ion batteries, allowing non-destructive 3D imaging across multiple spatial scales. Image quality is particularly important for observing the internal structure of lithium-ion batteries. During multiple rotations, the existence of cumulative errors and random errors in the rotary table leads to errors in the projection angle, affecting the imaging quality of XCT. The accuracy of the projection angle is an important factor that directly affects imaging. However, the impact of the projection angle on XCT reconstruction imaging is difficult to quantify. Therefore, the required precision of the projection angle sensor cannot be determined explicitly. In this research, we selected a common 18650 cylindrical lithium-ion battery for experiments. By setting up an XCT scanning platform and installing an angle sensor to calibrate the projection angle, we proceeded with image reconstruction after introducing various angle errors. When comparing the results, we found that projection angle errors lead to the appearance of noise and many stripe artifacts in the image. This is particularly noticeable in the form of many irregular artifacts in the image background. The overall variation and residual projection error in detection indicators can effectively reflect the trend in image quality. This research analyzed the impact of projection angle errors on imaging and improved the quality of XCT imaging by installing angle sensors on a rotary table.

## Full-text entities

- **Chemicals:** Lithium (MESH:D008094)

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC10892775/full.md

## Figures

9 figures with captions in the complete paper: https://tomesphere.com/paper/PMC10892775/full.md

## References

42 references — full list in the complete paper: https://tomesphere.com/paper/PMC10892775/full.md

---
Source: https://tomesphere.com/paper/PMC10892775