# UVC Box: An Effective Way to Quickly Decontaminate Healthcare Facilities’ Wheelchairs

**Authors:** Cloé Adam, Marius Colin, Romuald Stock, Laurent Weiss, Sophie C. Gangloff

PMC · DOI: 10.3390/life14020256 · 2024-02-16

## TL;DR

A UVC box can effectively and quickly disinfect wheelchairs in healthcare facilities, but its efficiency depends on the material and design of the objects being treated.

## Contribution

The study introduces a UVC box for decontaminating complex objects like wheelchairs and identifies material-specific effects on disinfection efficiency.

## Key findings

- A 5-minute UVC treatment reduces bacterial burden by more than 3 logs in Escherichia coli and Staphylococcus epidermidis.
- Rigid materials like steel and plastic show the lowest residual bacterial burdens after UVC treatment.
- Porous materials and surface treatments on metallic samples reduce UVC disinfection efficiency.

## Abstract

Disinfection in the hospital environment remains challenging, especially for wide and structurally complex objects such as beds or wheelchairs. Indeed, the regular disinfection of these objects with chemicals is manually carried out by healthcare workers and is fastidious and time-consuming. Alternative antibacterial techniques were thus proposed in the past decades, including the use of naturally antimicrobial UVC. Here, the antibacterial efficiency of a large UVC box built to accommodate wheelchairs was investigated through testing bacterial burden reductions on various parts of a wheelchair, with various support types and with several treatment durations. The results demonstrate a time-dependent antibacterial effect, with a strong burden reduction at only five minutes of treatment (>3-log median reduction in Escherichia coli and Staphylococcus epidermidis). The UVC flux and residual bacterial burden both significantly varied depending on the spatial location on the wheelchair. However, the nature of the support impacted the antibacterial efficiency even more, with residual bacterial burdens being the lowest on rigid materials (steel, plastics) and being the highest on tissue. On metallic samples, the nature of the alloy and surface treatment had various impacts on the antibacterial efficiency of the UVC. This study highlights the efficiency of the tested UVC box to efficiently and quickly decontaminate complex objects such as wheelchairs, but also gives rise to the warning to focus on rigid materials and avoid porous materials in the conception of objects, so as to ensure the efficiency of UVC decontamination.

## Linked entities

- **Species:** Escherichia coli (taxon 562), Staphylococcus epidermidis (taxon 1282)

## Full-text entities

- **Diseases:** bacterial (MESH:D001424)
- **Species:** Escherichia coli (E. coli, species) [taxon 562], Staphylococcus epidermidis (species) [taxon 1282]

## Figures

7 figures with captions in the complete paper: https://tomesphere.com/paper/PMC10890712/full.md

---