# Results of Utilizing Cerclage Wires in the Management of Intraoperative Vancouver B1 Fractures in Primary Total Hip Arthroplasties: A Retrospective Cohort Investigation into Clinical and Radiographic Outcomes

**Authors:** Caterina Rocchi, Vincenzo Di Matteo, Katia Chiappetta, Guido Grappiolo, Mattia Loppini

PMC · DOI: 10.3390/jcm13030819 · Journal of Clinical Medicine · 2024-01-31

## TL;DR

This study shows that using cerclage wires during surgery for a specific type of hip fracture after hip replacement is highly effective, with excellent short-term outcomes.

## Contribution

The study provides clinical evidence supporting the use of cerclage wires for intraoperative Vancouver B1 fractures in hip replacements.

## Key findings

- A 99% reoperation-free survival rate was observed at 6 months.
- Limb length discrepancy significantly improved post-surgery.
- Harris hip scores showed substantial improvement after treatment.

## Abstract

Background: Due to an increase in total hip arthroplasties (THAs), the incidence of periprosthetic hip fractures (PPHFs) is forecast to rise considerably in the next decades, with Vancouver B1 fractures (VB1) accounting for one third of total cases. Femur fixation with cerclages (with or without screws) is considered the current treatment option for intraoperative VB1. Methods: The study retrospectively includes data from patients who developed VB1 PPHFs during THAs from 3 December 2020 to 30 November 2022. The primary outcome of this study was to identify the reintervention-free survival rate. The secondary aim was to determine clinical and radiographic assessment at follow-up, based on Harris hip score (HHS) and limb length discrepancy (LLD). Results: Thirty-seven patients with a mean age of 60.03 ± 15.49 (22 to 77) years old were included. Overall, the Kaplan–Meier analysis estimated a reoperation-free survival rate of 99% (CI 95%) at 6 months. The mean limb length discrepancy (LLD) improved from −3.69 ± 6.07 (range −27.9 to 2.08) mm to 0.10 ± 0.67 (range −1.07 to 1.20) mm. The mean HHS improved from 42.72 ± 14.37 (range 21.00–96.00) to 94.40 ± 10.32 (range 56.00–100.00). Conclusions: The employment of cerclage wires represents an effective strategy for handling intraoperative VB1 fractures. Level III retrospective cohort study.

## Full-text entities

- **Diseases:** PPHFs (MESH:D057068), fractures (MESH:D050723), VB1 (MESH:C566196), limb length discrepancy (MESH:D007870)
- **Species:** Homo sapiens (human, species) [taxon 9606]

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/PMC10856186/full.md

## Figures

3 figures with captions in the complete paper: https://tomesphere.com/paper/PMC10856186/full.md

## References

24 references — full list in the complete paper: https://tomesphere.com/paper/PMC10856186/full.md

---
Source: https://tomesphere.com/paper/PMC10856186