Hybrid MCP-PMT characterisation on a testbeam with Cherenkov setup
G. Romolini, J. Alozy, R. Ballabriga, N. V. Biesuz, R. Bolzonella, M. Campbell, G. Cavallero, V. Cavallini, A. Cotta Ramusino, M. Fiorini, E. Franzoso, M. Guarise, X. Llopart Cudie, A. Saputi, D. Vincenzi

TL;DR
This paper reports on the testing of a new hybrid MCP-PMT photodetector with CMOS ASIC at CERN, demonstrating single photon Cherenkov detection with high gain and good timing resolution.
Contribution
It introduces a novel hybrid MCP-PMT design with integrated CMOS ASIC and evaluates its performance in a high-energy testbeam environment.
Findings
Single photon Cherenkov detection achieved
Timing resolution of approximately 280 ps
Operation at a gain of 10^4
Abstract
A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10 gain and with timing resolution of about 280~ps.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsRadiation Detection and Scintillator Technologies · Particle Detector Development and Performance · Photocathodes and Microchannel Plates