3-D Markerless Tracking of Human Gait by Geometric Trilateration of Multiple Kinects
Lin Yang, Bowen Yang, Haiwei Dong, and Abdulmotaleb El Saddik

TL;DR
This paper presents a novel markerless gait tracking system using three Kinect v2 sensors and geometric trilateration, achieving higher accuracy and synchronization than single sensors and commercial systems.
Contribution
The paper introduces a trilateration-based method for 3D gait tracking with multiple Kinects and a synchronization mechanism for improved accuracy.
Findings
Trilateration with three Kinects outperforms single Kinect accuracy.
Achieved 98.37% frames with less than 1 ms timing error.
System's accuracy validated against a commercial medical system.
Abstract
In this paper, we develop an integrated markerless gait tracking system with three Kinect v2 sensors. A geometric principle-based trilateration method is proposed for optimizing the accuracy of the measured gait data. To tackle the data synchronization problem among the Kinect clients and the server, a synchronization mechanism based on NTP (Network Time Protocol) is designed for synchronizing the server and Kinect clients' clocks. Furthermore, a time schedule is designed for timing each Kinect client's data transmission. In the experiment, participants are asked to perform a 60 s walk while the proposed tracking system obtains the participant's gait data. Six joints (including left hip, right hip, left knee, right knee, left ankle and right ankle) of the participants are tracked where the obtained gait data are described as 6000 {movements} of joint positions (1000 {movements} for each…
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.