Fabrication experience of the pre-production PIP-II SSR2 cavities at Fermilab
M. Parise, D. Passarelli, P. Berrutti, V. Roger, D. Longuevergne, P., Duchesne

TL;DR
This paper discusses the design, fabrication, and testing experiences of the SSR2 cavities for the PIP-II project at Fermilab, highlighting lessons learned and validation processes.
Contribution
It presents the finalized mechanical design and fabrication experience of the SSR2 cavities, including insights on quality control, interfaces, and development studies.
Findings
Successful fabrication of pre-production SSR2 cavities
Lessons learned in quality control and interface management
Validation tests confirming design robustness
Abstract
The Proton Improvement Plan-II (PIP-II, [1]) linac will include 35 Single Spoke Resonators type 2 (SSR2). A total of eight pre-production SSR2 jacketed cavities will be procured and five installed in the first pre-production cryomodule. The mechanical design of the jacketed cavity has been finalized and it will be presented in this paper along with fabrication and processing experience. The importance of interfaces, quality controls and procurement aspects in the design phase will be remarked as well as lessons learned during the fabrication process. Furthermore, development studies will be presented together with other design validation tests.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.