Room Temperature, Quantum-Limited THz Heterodyne Detection? Not Yet
J. Zmuidzinas, B. Karasik, A. R. Kerr, M. Pospieszalski

TL;DR
The paper critically examines a recent claim of near quantum-limited THz heterodyne detection at room temperature, highlighting methodological flaws and lack of supporting data, thus questioning the validity of the original claim.
Contribution
It provides a critical analysis of a proposed THz detection scheme, emphasizing the importance of proper experimental validation and reporting of key parameters.
Findings
The claimed near quantum-limited sensitivity is unsubstantiated.
Experimental methodology in the original paper is flawed.
Conversion loss and impedance measurements are crucial for validation.
Abstract
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could readily have been measured and reported as a consistency check. The paper thus offers no reliable experimental evidence that substantiates the claimed sensitivities. To the contrary, the very high value reported for their photomixer impedance strongly suggests that the conversion loss is quite poor and that the actual sensitivity is far worse than claimed.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsSuperconducting and THz Device Technology · Terahertz technology and applications · Physics of Superconductivity and Magnetism
Room Temperature, Quantum-Limited THz Heterodyne Detection?
Not Yet
J. Zmuidzinas
California Institute of Technology 301-17, 1200 E. California Blvd. , Pasadena CA 91125. [email protected]
B. Karasik
Jet Propulsion Laboratory 168-314, California Institute of Technology, 4800 Oak Grove Drive, Pasadena CA 91109
A. R. Kerr
National Radio Astronomy Observatory, 1180 Boxwood Estate Road, Charlottesville VA 22903
M. Pospieszalski
National Radio Astronomy Observatory, 1180 Boxwood Estate Road, Charlottesville VA 22903
Arising from N. Wang et al., Nature Astronomy (2019)
https://doi.org/10.1038/s41550-019-0828-6
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could readily have been measured and reported as a consistency check. The paper thus offers no reliable experimental evidence that substantiates the claimed sensitivities. To the contrary, the very high value reported for their photomixer impedance strongly suggests that the conversion loss is quite poor and that the actual sensitivity is far worse than claimed.
THz heterodyne detection has been used in astronomy for over three decades [4] and is primarily of interest for high-resolution spectroscopy [5]. An illustrative application is the measurement of rotational transitions of isotopologues of water vapor to estimate the D/H ratio in comets – indeed, recent data from the SOFIA airborne observatory have reactivated the debate on whether the water in the Earth’s oceans was delivered by comets [6]. To date, the best detection sensitivities have been achieved using cryocooled superconducting devices [5] such as the superconductor-insulator-superconductor (SIS) receivers that enable ALMA [7] or the hot-electron bolometers (HEB) used in the HIFI instrument on the Herschel Space Observatory [8]. However, other THz space instruments [9] have generally not used cryocooled detectors due to power, mass, and cost constraints, thereby incurring a sensitivity penalty of or more. If the sensitivities reported by Wang et al. were correct, this severe penalty for ambient-temperature operation would be erased and numerous applications would be enabled.
The sensitivity of a heterodyne receiver is usually reported as a double sideband (DSB) receiver noise temperature . By definition, is the Rayleigh-Jeans temperature of a perfect blackbody source that, when illuminating the receiver’s THz-frequency input, would contribute the same noise power at the output of the final IF amplifier (typically in the GHz range) as contributed by all of the different components of the THz receiver. The sensitivity of a heterodyne receiver is subject to the quantum limit [10] arising from the Heisenberg uncertainty principle, corresponding to for the DSB noise temperature. As shown in their Figure 3c, the sensitivity claimed by Wang et al. for their room-temperature receiver lies impressively close to this limit, matching or exceeding the performance of cryocooled SIS or HEB receivers.
Unfortunately, the experimental procedure used by Wang et al. to measure sensitivity is fatally flawed. The standard technique for determining the noise temperature is the “-factor” method where the IF noise power is measured using two blackbodies with different Rayleigh-Jeans temperatures, and . The -factor is the ratio of these two measurements,
[TABLE]
from which the receiver sensitivity is calculated according to
[TABLE]
In their Methods section, Wang et al. claim to measure sensitivities “using the standard -factor method”, but this is not the case. In that section, we learn that:
“…the output IF signal at GHz is detected by a power meter (Mini-Circuits ZX47-60LN) using a lock-in amplifier with the 100 kHz modulation reference frequency…”.
The output of the ZX47-60LN power detector [11] is a voltage that responds logarithmically to the IF power ; one could presumably use the measured DC voltage along with a calibration curve to obtain , as needed for calculation of the -factor. However, a lock-in amplifier does not measure the DC voltage; rather, it measures changes in the voltage that occur at a 100 kHz rate in response to a modulation. Their Methods section states
“…the optical pump beam from the dual DFB laser system is modulated using an acousto-optic modulator … at a 100 kHz rate”
meaning that the laser source that drives the photomixer is being turned on and off at the 100 kHz lock-in frequency. Thus, the lock-in reports a quantity that is related to the change in the IF power that occurs in response to turning the laser on and off, . Given their statement regarding use of the -factor method, Wang et al. presumably take the ratio of such lock-in readings for hot and cold loads. Although not explicitly stated in their paper, they apparently make the assumption that the response of their logarithmic ZX47-60LN detector is linear for small perturbations, in which case taking the ratio yields
[TABLE]
This quantity is very different than the standard factor. In particular, remains invariant if a constant is added to all power levels, e.g., as a result of a uniform increase of the IF amplifier noise contribution, whereas is definitely not invariant. Furthermore, the paper makes no mention of measurements of or , and because this information is missing, it is not possible to convert the reported values of into corrected values for . Noise temperatures calculated using are meaningless, and can be radically different from the true noise temperatures calculated using . Thus, one cannot place any confidence in the sensitivities reported by Wang et al. in their Figure 3c.
What would a properly executed -factor measurement reveal about the performance of their device? Judging from the large photomixer impedance reported by Wang et al., the sensitivity is likely worse than claimed. Our argument involves the mixer conversion loss , which has a direct impact on receiver sensitivity according to
[TABLE]
The mixer noise temperature cannot be negative, and the noise temperature of the first-stage low-noise amplifier sets a lower bound for the noise of the IF system, . Thus, must hold. Unfortunately, Wang et al. do not report any values for the conversion loss , apparently missing several opportunities for measuring while collecting data for their figures 2 and 3. Wang et al. also do not report measurements for or , although according to the manufacturer’s data sheet for their Mini Circuits ZRL-1150 first-stage amplifier [11], we may take K as a reasonable value including cable losses. Thus, the K noise temperatures reported by Wang et al. at frequencies up to 1 THz require a conversion loss no higher than , or 3 dB. This is an extremely low value, comparable to the conversion loss of a well-optimized SIS mixer; if their 300 K mixer contributes any noise at all, the conversion loss would need to be even lower.
The actual conversion loss is likely dB worse, as indicated by the photomixer impedance reported by Wang et al. on page 8 of the supplemental information:
“… is the average electrical resistance of the photomixer at a 30 mW pump power. The estimated value from the numerical simulations is in agreement with the experimentally measured photomixer resistance of .”
This large impedance is in line with data on other LTG-GaAs photomixers including those previously studied by this group [3]. Thus, there is a severe impedance mismatch between the photomixer and the IF amplifier, corresponding to a coupling loss of 21 dB. For the overall conversion loss to be no worse than 3 dB, as required by the reported sensivity, the photomixer would need to have an internal conversion gain of at least 18 dB! Internal conversion gain in this device seems implausible, especially such a large value, given the lack of any measurements of conversion loss and the absence of a clear physical mechanism for gain.
Indeed, the theory of operation presented by Wang et al. makes no mention of conversion gain. According to equation (6) of their supplemental information, they assume a linear, local relationship between the current density and THz electric field at frequency . For GHz where ps is the stated carrier lifetime, the response is essentially instantaneous and their equation (6) is equivalent to Ohm’s law . Here is the (real) conductivity that varies with time and position due to the photogeneration of carriers by the two lasers with beat frequency . The equation simply describes current flow in an ordinary resistor, and leads to the circuit version of Ohm’s law , or when the conductivity is time dependent. Here and are the current and voltage across the terminals of the THz spiral antenna, and the is the time-dependent photomixer resistance as seen from the antenna terminals. Thus, the theory offered by Wang et al. places the device into a well-known class of “resistive mixers” that includes diode mixers [12] and FET mixers [13], which are not capable of conversion gain and in fact are subject to a theoretical minimum conversion loss of 3 dB [14, 15]. Their theory is therefore incompatible with their claimed sensitivity, which requires a large internal conversion gain to overcome the severe IF impedance mismatch as discussed above. While the resistive mixer argument strictly holds only for GHz, one expects photomixer performance to deteriorate at higher frequencies [2], as Wang et al. themselves state when discussing the utility of the short lifetime ps to “recombine the slow photocarriers that degrade the terahertz-to-RF conversion efficiency”.
We close by offering recommendations the authors could adopt to address our concerns and to build confidence in their results:
- •
Eliminate the lock-in and use the standard -factor method to determine . It may be helpful to add IF gain to boost the detector output and to use a square-law IF detector rather than a logarithmic detector.
- •
Measure and report the mixer conversion loss, an urgently needed consistency check. This could be measured during the hot/cold load procedure if the IF system is calibrated.
- •
Measure the noise temperature of the IF system, and estimate the IF contribution to the receiver noise using the measured conversion loss.
- •
Experimentally demonstrate that the receiver response is truly heterodyne, e.g., by using infrared-blocking filters, THz passband filters, and ideally gas-cell measurements of molecular absorption lines.
The research by BK was performed at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration. The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1[1] Wang, N., Cakmakyapan, S., Lin, Y.-J., Javadi, H. & Jarrahi, M. Room-temperature heterodyne terahertz detection with quantum-level sensitivity. Nature Astronomy (2019).
- 2[2] Brown, E., Mc Intosh, K., Nichols, K. & Dennis, C. Photomixing up to 3.8 T Hz in low-temperature-grown Ga As. Applied Physics Letters 66 , 285–287 (1995).
- 3[3] Berry, C. W., Wang, N., Hashemi, M. R., Unlu, M. & Jarrahi, M. Significant performance enhancement in photoconductive terahertz optoelectronics by incorporating plasmonic contact electrodes. Nature communications 4 , 1622 (2013).
- 4[4] Boreiko, R., Betz, A. & Zmuidzinas, J. Heterodyne spectroscopy of the 158 micron C II line in M 42. The Astrophysical Journal 325 , L 47–L 51 (1988).
- 5[5] Zmuidzinas, J. & Richards, P. L. Superconducting detectors and mixers for millimeter and submillimeter astrophysics. Proceedings of the IEEE 92 , 1597–1616 (2004).
- 6[6] Lis, D. C. et al. Terrestrial deuterium-to-hydrogen ratio in water in hyperactive comets. Astronomy & Astrophysics 625 , L 5 (2019).
- 7[7] Wootten, A. & Thompson, A. R. The Atacama large millimeter/submillimeter array. Proceedings of the IEEE 97 , 1463–1471 (2009).
- 8[8] Pilbratt, G. et al. Herschel Space Observatory-An ESA facility for far-infrared and submillimetre astronomy. Astronomy & Astrophysics 518 , L 1 (2010).