# The $^6$Li/$^7$Li isotopic ratio in the metal-poor binary CS22876--032

**Authors:** J.I. Gonz\'alez Hern\'andez, P. Bonifacio, E. Caffau, H.G. Ludwig, M., Steffen, L. Monaco, R. Cayrel

arXiv: 1907.05109 · 2019-08-14

## TL;DR

This study measures the lithium isotopic ratio in a very metal-poor binary star, finding no significant presence of $^6$Li, and providing insights into primordial nucleosynthesis and stellar processes.

## Contribution

First high-resolution 3D-NLTE analysis of $^6$Li/$^7$Li ratio in the metal-poor binary CS 22876--032, setting new upper limits at extremely low metallicity.

## Key findings

- No detection of $^6$Li, upper limit <10%
- Li abundance of primary star is 2.17 dex
- Secondary star's Li abundance is 1.55 dex

## Abstract

We present high-resolution and high-quality UVES spectroscopic data of the metal-poor double-lined spectroscopic binary CS 22876--032 ([Fe/H] $\sim -3.7$ dex), with the goal to derive the $^6$Li/$^7$Li isotopic ratio by analysing the \ion{Li}{i} $\lambda$~670.8~nm doublet. We coadd all 28 useful spectra normalised and corrected for radial velocity to the rest frame of the primary star. We fit the Li profile with a grid of the 3D-NLTE synthetic spectra, to take into account the line profile asymmetries induced by stellar convection, and perform Monte Carlo simulations to evaluate the uncertainty of the fit of the Li line profile. We check that the veiling factor does not affect the derived isotopic ratio, $^6$Li/$^7$Li, and only modifies the Li abundance, A(Li), by about 0.15~dex. The best fit of the Li profile of the primary star provides A(Li)~$ = 2.17 \pm 0.01$~dex and $^6$Li/$^7$Li~$=8^{+2}_{-5}$\% at 68\% confidence level. In addition, we improve the Li abundance of the secondary star at A(Li)~$= 1.55 \pm 0.04$~dex, which is about 0.6~dex lower than that of the primary star. The analysis of the Li profile of the primary star is consistent with no detection of $^6$Li and provides an upper-limit to the isotopic ratio of $^6$Li/$^7$Li~$< 10$\% at this very low metallicity, about 0.5~dex lower in metallicity than previous attempts for detection of $^6$Li in extremely metal poor stars. These results do not solve or worsen the cosmological $^7$Li problem, nor support the need for non standard $^6$Li production in the early Universe.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/1907.05109/full.md

## Figures

9 figures with captions in the complete paper: https://tomesphere.com/paper/1907.05109/full.md

## References

52 references — full list in the complete paper: https://tomesphere.com/paper/1907.05109/full.md

---
Source: https://tomesphere.com/paper/1907.05109