This study determines fundamental parameters of three magnetic chemically peculiar stars using spectroscopy and interferometry, demonstrating the reliability of spectroscopic methods for fainter stars where direct measurements are challenging.

## Contribution

It presents a self-consistent spectroscopic analysis method that accounts for chemical peculiarities and validates it with interferometric radius measurements.

## Key findings

- Spectroscopic analysis yields accurate stellar radii consistent with interferometry.
- Method effectively determines parameters for chemically peculiar stars.
- Spectroscopic techniques are reliable for faint stars beyond interferometric capabilities.

## Abstract

The determination of fundamental parameters of stars is one of the main tasks of astrophysics. For magnetic chemically peculiar stars, this problem is complicated by the anomalous chemical composition of their atmospheres, which requires special analysis methods. We present the results of the effective temperature, surface gravity, abundance and radius determinations for three CP stars HD 188041, HD 111133, and HD 204411. Our analysis is based on a self-consistent model fitting of high-resolution spectra and spectrophrotometric observations over a wide wavelength range, taking into account the anomalous chemical composition of atmospheres and the inhomogeneous vertical distribution for three chemical elements: Ca, Cr, and Fe. For two stars, HD 188041 and HD 204411, we also performed interferometric observations which provided us with the direct estimates of stellar radii. Parameters for another 8 CP stars are collected. Comparison of the radii determined from the analysis of spectroscopic/spectrophotometric observations with direct measurements of the radii by interferometry methods for seven CP stars shows that the radii agree within the limits of measurement errors, which proves indirect spectroscopic analysis capable of proving reliable determinations of the fundamental parameters of fainter Ap stars that are not possible to study with modern interferometric facilities.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/1907.03598/full.md

## Figures

19 figures with captions in the complete paper: https://tomesphere.com/paper/1907.03598/full.md

## References

76 references — full list in the complete paper: https://tomesphere.com/paper/1907.03598/full.md

---
Source: https://tomesphere.com/paper/1907.03598