# Bunch Length and Energy Measurements in the Bunch-Compressor of a   Free-Electron-Laser

**Authors:** G.L.Orlandi, R.Xue, H.Brands, F.Frei, Z. Geng, S.Bettoni

arXiv: 1905.08081 · 2019-07-24

## TL;DR

This paper presents a non-invasive method to measure electron bunch length and energy distribution in SwissFEL's magnetic chicane using synchrotron-radiation imaging, correlating beam parameters with RF injector settings.

## Contribution

It introduces a novel approach to determine bunch length and energy distribution non-invasively via SRM imaging and RF parameter correlation at SwissFEL.

## Key findings

- Successful shot-by-shot bunch length measurement using SRM
- Correlation established between SRM images and RF-induced energy chirp
- Validation of the method with SwissFEL beam parameters

## Abstract

At SwissFEL, a fully non-invasive characterization of the beam energy distribution can be performed by means of a Synchrotron-Radiation-Monitor (SRM) imaging in the visible the transverse profile of the electron beam in a magnetic chicane. Under conditions of off-crest acceleration in the SwissFEL injector, according to a first order Taylor series expansion, the distribution of the relative energy of the electron beam can be linearly expressed as a function of the distribution of the electron longitudinal coordinates via the coefficient of the rf induced beam energy chirp. It is hence possible to express the distribution of the electron longitudinal coordinates at the entrance of the magnetic chicane of SwissFEL as a function of the distribution of the dispersed electron trajectories in the horizontal plane of the magnetic chicane. Machine parameters and instrument data at SwissFEL can be beam-synchronously acquired. A shot-by-shot correlation between the analysis results of the SRM camera images and the linear coefficient of the beam energy chirp resulting from the rf parameters of the injector can be hence established. Finally, taking into account the compression factor of the magnetic chicane, the electron bunch length at the exit of the magnetic chicane can be expressed as a function of the horizontal size of the electron beam imaged by the SRM. Bunch-length measurements performed by means of the SRM in the first magnetic chicane of SwissFEL will be presented.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/1905.08081/full.md

## Figures

9 figures with captions in the complete paper: https://tomesphere.com/paper/1905.08081/full.md

## References

8 references — full list in the complete paper: https://tomesphere.com/paper/1905.08081/full.md

---
Source: https://tomesphere.com/paper/1905.08081