Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
A. Paiella, E. S. Battistelli, M. G. Castellano, I. Colantoni, F., Columbro, A. Coppolecchia, G. D'Alessandro, P. de Bernardis, S. Gordon, L., Lamagna, H. Mani, S. Masi, P. Mauskopf, G. Pettinari, F. Piacentini, G., Presta

TL;DR
This paper presents the development and validation of LEKID arrays and their readout electronics for the OLIMPO experiment, aimed at astrophysical observations in multiple spectral bands.
Contribution
It introduces optimized LEKID arrays and a comprehensive readout system tailored for balloon-borne astrophysics applications, demonstrating their suitability in a space-like environment.
Findings
LEKID arrays operate effectively at 0.3 K with high quality factors.
The readout electronics achieve low noise performance suitable for astrophysical signals.
Successful characterization and validation of the detector system for OLIMPO.
Abstract
Kinetic Inductance Detectors (KIDs) are superconductive lowtemperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides;…
| \brChannel | |
|---|---|
| \mr150 | |
| 250 | |
| 350 | |
| 460 | |
| \br |
| \br T | LNA | Gain | Noise Power | Noise Temperature | Notes |
|---|---|---|---|---|---|
| Voltage | @ LNA input | ||||
| \mr4 | 1.6 | 33 | 192.00.2 | 4.570.21 | |
| 44 | 1.5 | 32.1 | 189.10.2 | 8.910.41 | |
| 44 | 1.6 | 32.4 | 189.40.2 | 8.310.38 | |
| 44 | 1.7 | 32.7 | 189.70.2 | 7.760.36 | Measurements performed |
| 44 | 1.8 | 32.9 | 189.90.2 | 7.410.34 | by us in a laboratory cryostat |
| 44 | 1.9 | 33.0 | 190.00.2 | 7.240.33 | |
| 44 | 2.0 | 33.1 | 190.10.2 | 7.080.33 | |
| 44 | 2.1 | 33.2 | 190.20.2 | 6.920.32 | |
| \mr10 | 1.6 | 33 | 5 | ||
| 20 | 1.6 | 6 | provided by ASU | ||
| 300 | 2.1 | 30 | 45 | ||
| \br |
| \brChannel | |
|---|---|
| \mr150 | |
| 250 | |
| 350 | |
| 460 | |
| \br |
| \brComponent | Gain (G) | gain compression point | Noise Figure (NF) | |
| @ input | @ output | |||
| \mrAmp. 1 | 20 | 2 | 22 | 0.4 |
| Amp. 2 | 22.5 | 9.5 | 13 | 2.7 |
| IQ demodulator | 4.4 | 13 | 17.4 | 13.2 |
| \br | ||||
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
A Paiella1,2
E S Battistelli1,2
M G Castellano3
I Colantoni*3,*666Present address: School of Cosmic Physics, Dublin Institute for Advanced Studies, 31 Fitzwilliam Place, D02 XF86, Dublin, Ireland.
F Columbro1,2
A Coppolecchia1,2
G D’Alessandro1,2
P de Bernardis1,2
S Gordon4
L Lamagna1,2
H Mani4
S Masi1,2
P Mauskopf
G Pettinari3
F Piacentini1,2 and G Presta1
1 Dipartimento di Fisica, Sapienza Università di Roma, P.le A. Moro 2, 00185 Roma, Italy
2 Istituto Nazionale di Fisica Nucleare, Sezione di Roma, P.le A. Moro 2, 00185 Roma, Italy
3 Istituto di Fotonica e Nanotecnologie - CNR, Via Cineto Romano 42, 00156 Roma, Italy
4 School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287, USA
5 Department of Physics, Arizona State University, Tempe, AZ 85257, USA [email protected]
Abstract
Kinetic Inductance Detectors (KIDs) are superconductive low–temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn–coupled focal planes of the OLIMPO balloon–borne telescope, working in the spectral bands centered at , , , and . This is aimed at measuring the spectrum of the Sunyaev–Zel’dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space–like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room–temperature optical system and they operate at a temperature of . The LEKID planar superconducting circuits are designed to resonate between 100 and , and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a cold part, which includes a low noise amplifier, a dc–block, coaxial cables, and power attenuators; and a room–temperature part, FPGA–based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
1 Introduction
In the last thirty years, precision cosmology has achieved important goals through measurements of the Cosmic Microwave Background (CMB) radiation such as its spectrum [1], the anisotropies [2], the E–mode component of the polarization [3], and the B–mode component of the polarization due to gravitational lensing from dark matter structure [4]. Yet, the B-mode power spectrum from inflation and the spectral distortions still remain elusive as well as the spectroscopic measurement of the Sunyaev–Zel’dovich (SZ) effect.
The OLIMPO experiment [5] is aimed at measuring the SZ effect which is a CMB anisotropy in the direction of galaxy clusters, due to the inverse Compton scattering of low energy CMB photons by the high energy electrons of the hot gas present in the intra–cluster medium. SZ effect measurements represent an interesting tool to study the morphological and dynamical state of clusters, to probe the CMB temperature evolution with the redshift, to constraint cosmological parameters, and to search for previously unknown clusters by looking at their SZ signature in the microwave sky [6, 7].
OLIMPO measures SZ signals with a technique so far unattempted in this kind of obervations: it performs a spectroscopic map of the SZ effect with a differential interferometric instrument, working above the atmosphere, and provides efficient and unbiased decontamination of the SZ and CMB signals from all the foregrounds along the same line of sight [8], thus increasing the accuracy on the estimate of the astrophysical quantities involved in the physics of the effect.
The OLIMPO experiment has been, therefore, designed as a large balloon–borne mm–wave observatory, with a aperture telescope, equipped with a room–temperature differential Fourier transform spectrometer (DFTS) [9], and four low–temperature detector arrays, centered at 150, 250, 350, and , exploring the negative, zero, and positive regions of the SZ spectrum. The detector arrays, consisting of horn–coupled lumped element kinetic inductance detectors (LEKIDs), are cooled to about by a 3He fridge, accomodated inside a wet N2 plus 4He cryostat. The detector arrays are fed and read out coupled by means of two independent bias–readout lines and two FPGA–based electronics.
Kinetic inductance detectors are superconductive photon detectors, where the radiation is detected by sensing changes of the kinetic inductance. A superconductor, cooled below its critical temperature , presents two populations of electrons: quasiparticles and Cooper pairs, bound states of two electrons with binding energy . If pair-breaking radiation () is absorbed in a superconducting film, it breaks Cooper pairs, producing a change in the population relative densities, and thus in the kinetic inductance. For these reasons, in the lumped element configuration, a superconducting strip is properly shaped and sized in order to perform like a radiation absorber, and this structure, which is an inductor as well, is coupled to a capacitor to form a superconductive high quality factor resonator. In this way, the change in kinetic inductance, due to the incident radiation, produces a change in the resonant frequency and in the quality factor, which can be sensed by measuring the change in the amplitude and phase of the bias signal of the resonator, transmitted past the resonator through a feedline.
The KID design and readout scheme are intrinsically multiplexable for large–format arrays, provided that the resonant frequencies of the individual resonators coupled to the same feedline are adjusted to unique values, for instance by changing the capacitor size. In this way, entire arrays can be fed and read out thanks to an electronics chain made of cold components, including low noise amplifiers (LNAs), dc–blocks, coaxial cables, and power attenuators; and a room–temperature stage, where an FPGA-based electronics, coupled to an ADC/DAC board, is used to generate one bias tone per resonator. This solution allows to feed and monitor the amplitude and phase of the bias signals of all the resonators at the same time, while physically connecting the cold stage to the room–temperature with one cable only.
KID technology has been already proven in ground–based experiments [10], and for its features seems to be the optimal solution for next–generation space–borne CMB experiments [11, 12], but it still needs to be demonstrated in a representative environment for space applications. OLIMPO, which was operated from the stratosphere, is therefore a natural testbed for KIDs in space–like conditions.
2 Detectors and cold electronics
The first constraint in the optimization process of a detector system is always the target science for which it will be built. In the OLIMPO case, moreover, it has to fit an already developed cryogenic and optical system. This implies that the first step is the choice of the material of the superconducting film and the dielectric substrate, the size of the detector arrays, the geometry and size of the absorbers, the geometry and size of the radiation couplers, the number of detectors per array, and the illumination configuration. These steps have been performed through optical simulations.
The second step concerns the optimization of the readout scheme: the geometry and size of the feedline; the geometry and size of the capacitors, on which the resonant frequencies of the resonators depend; and the coupling between the resonators and the feedline. This optimization has been done through electrical simulations.
The last step regards the optimization of the cold electronics: the choice of the material and size of the coaxial cables; the magnitude of the power attenuators; the gain, noise, and operation temperature of the cryogenic amplifier.
2.1 KID optimization, fabrication and results
The detailed description of the optimization and fabrication of the OLIMPO detector systems and the measurement results can be found in [13, 14].
All the four arrays are fabricated in a thick aluminum film deposited on silicon substrates of different thickness depending on the observed radiation frequency. The substrate acts also as a backshort, since the face opposite to the detectors has been coated with aluminum. The properties of different aluminum film thicknesses have been measured as described in [15], and the results have been used for the optical simulations. A compromise between optical simulation results and critical temperature (on which the optimal working temperature and the minimum detectable radiation frequency depend) forced us to choose for the aluminum film thickness. For this film, we measured the critical temperature, 1.31\text{,}\mathrm{K}; the residual resistance ratio, ${\rm RRR}=3.1$; the sheet resistance, $R_{s}=$1.21\text{\,}\Omega\mathrm{/}\Box, and the surface inductance, 1.38\text{,}\mathrm{p}\mathrm{H}\mathrm{/}\Box$$.
The optimal absorber solution results to be a front–illuminated IV order Hilbert pattern, where the characteristic length scales with the observed radiation wavelength. The 150 and 250 GHz arrays are coupled to the radiation via a single–mode waveguide, while the 350 and 460 GHz are coupled via a single–mode flared waveguide. The number of detectors per array is 23, 39, 25 and 43 for the 150, 250, 350 and array, respectively.
The capacitors of the KIDs have been designed so that the lumped element condition is satisfied for all the resonators and the resonant frequencies fall into the range MHz. This is done by means of large capacitors, which have also the advantage of reducing the TLS (two–level system) noise [16]. Moreover, the resonant frequencies are such that the and the arrays can be fed and read out with the same line as well as the and the arrays. In this way, each readout electronics manages about 65 detectors. Each detector is coupled to a –matched microstrip feedline (the width of which is different array by array) by means of capacitors, designed to constraint the coupling quality factor to about guaranteeing, thus, a quite large detector dynamics, and that the total quality factor results dominated by the coupling one.
The arrays have been fabricated at the IFN–CNR. The detectors have been realized by electron–beam litography, electron–gun evaporation and lift–off [17] on high–quality, high–resistivity (10\text{,}\mathrm{k}\Omega,\mathrm{c}\mathrm{m}$$) intrinsic Si(100) wafers, double–side polished. The sample holders of the detector arrays are made of ergal alloy (aluminum 7075) as well as the horn arrays, in order to guarantee good thermalization and low power losses through the horns.
The OLIMPO detectors have been fully characterized: the electrical properties, such as the quality factors and the resonant frequencies, have been measured in a dark laboratory cryostat and result in agreement with the simulations; the optical performance has been measured in the OLIMPO cryostat and results in a Rayleigh-Jeans noise equivalent temperature lower than under a blackbody load of about , for all the OLIMPO arrays, and a global optical efficiency of about 10%, averaged over the four channels.
2.2 Cold electronics optimization
With cold electronics we mean the components placed inside the cryostat, necessary to feed and read out the detectors. These components include coaxial cables, power attenuators, low noise amplifiers and dc–blocks. They have to be chosen in such a way that the noise equivalent power (NEP) of the active components of the cold electronics is lower than the expected noise equivalent power of the detectors.
Theoretically, the noise of a KID is mainly due to the generation–recombination noise (the TLS noise can be neglected by design), thus its NEP can be evaluated as
[TABLE]
where is half Cooper pair binding energy, with the Boltzmann constant, is the quasiparticle number, and is the quasiparticle lifetime (measured in [14]). For the OLIMPO detectors, the generation–recombination NEP is collected in table 1.
As we already said, a KID is a superconductive resonator, which is optimally sensitive when operated close to its resonant frequency. This means that, since the quality factors are very high, due to the superconductor properties, and thus the resonances are very deep, the readout power has to be amplified. This is done by means of a cryogenic low noise amplifier, able to amplify the signal output from the detectors, with very low intrinsic noise. For the OLIMPO experiment, the two LNAs, necessary for the two readout lines, have been provided by Arizona State University111http://thz.asu.edu/products.html (ASU) [18]. These amplifiers dissipate about each (1.6\text{,}\mathrm{V} and $I=$8\text{\,}\mathrm{m}\mathrm{A} at ), and amplify , with a noise temperature of , and a gain compression point, referred to the input, of at , for a signal. The noise equivalent power associated to the cryogenic amplifier is given by
[TABLE]
where is the noise tempertaure, and is the total readout power at the LNA input.
Since the OLIMPO cryostat does not feature a stage, and since the coldest stage where they can be mounted is the vapor 4He shield, at a temperature of about , we need to extrapolate the values of the LNA noise temperature at , in order to compare the NEP associated to the LNA and the generation–recombination one.
This has been done by combining the measurements provided by ASU at 10, 20 and , with the measurements performed by us in a laboratory cryostat at 4 and . Since is the temperature closest to at which we were able to cool the amplifier quickly, the measurements at this temperature have been performed at different supply voltages. All these data are collected in table 2.2. The noise measurements have been done through an Anritsu MS2717B spectrum analyzer, set to a resolution bandwith 1\text{,}\mathrm{H}\mathrm{z}$$, at the LNA output, and have been scaled to the LNA input thanks to the gain measured with an Anritsu M52034B vector network analyzer (VNA). All these measurements refer to . The conversion between noise power and noise temperature is given by
[TABLE]
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1[1] Fixsen D J, Cheng E S, Gales J M, Mather J C et al. 1996 Astrophys. J. 473 576 URL http://stacks.iop.org/0004-637X/473/i=2/a=576
- 2[2] Planck Collaboration, Adam R, Ade P A R, Aghanim N et al. 2016 Astron. Astrophys. 594 A 1 URL https://doi.org/10.1051/0004-6361/201527101
- 3[3] Planck Collaboration, Ade P A R, Aghanim N, Arnaud M et al. 2016 Astron. Astrophys. 594 A 13 URL https://doi.org/10.1051/0004-6361/201525830
- 4[4] Ade P A R, Ahmed Z, Aikin R W, Alexander K D et al. 2016 Astrophys. J. 833 228 URL http://stacks.iop.org/0004-637X/833/i=2/a=228
- 5[5] Coppolecchia A, Ade P, Amico G, Battistelli E et al. 2013 OLIMPO: A 4-bands detectors array for balloon-borne observations of the Sunyaev-Zel’dovich effect. New Horizons for Observational Cosmology
- 6[6] De Zotti G, González-Nuevo J, Lopez-Caniego M, Negrello M et al. 2018 J. Cosmol. Astropart. P. 2018 020 URL http://stacks.iop.org/1475-7516/2018/i=04/a=020
- 7[7] Melin J B, Bonaldi A, Remazeilles M, Hagstotz S et al. 2018 J. Cosmol. Astropart. P. 2018 019 URL http://stacks.iop.org/1475-7516/2018/i=04/a=019
- 8[8] de Bernardis P, Colafrancesco S, D’Alessandro G, Lamagna L et al. 2012 Astron. Astrophys. 538 A 86 URL https://doi.org/10.1051/0004-6361/201118062