# Deep Network for Capacitive ECG Denoising

**Authors:** Vignesh Ravichandran, Balamurali Murugesan, Sharath M, Shankaranarayana, Keerthi Ram, Preejith S.P, Jayaraj Joseph, Mohanasankar, Sivaprakasam

arXiv: 1903.12536 · 2019-04-01

## TL;DR

This paper introduces a deep learning model for denoising capacitive ECG signals, enabling more accurate long-term cardiac monitoring in everyday environments despite motion artifacts.

## Contribution

It presents a novel end-to-end deep neural network with a joint loss function for effective cECG denoising, improving morphological analysis capabilities.

## Key findings

- Achieved MSE of 0.167 in denoising performance
- Cross correlation of 0.476 indicates good signal similarity
- Demonstrated feasibility of morphological analysis on filtered cECG

## Abstract

Continuous monitoring of cardiac health under free living condition is crucial to provide effective care for patients undergoing post operative recovery and individuals with high cardiac risk like the elderly. Capacitive Electrocardiogram (cECG) is one such technology which allows comfortable and long term monitoring through its ability to measure biopotential in conditions without having skin contact. cECG monitoring can be done using many household objects like chairs, beds and even car seats allowing for seamless monitoring of individuals. This method is unfortunately highly susceptible to motion artifacts which greatly limits its usage in clinical practice. The current use of cECG systems has been limited to performing rhythmic analysis. In this paper we propose a novel end-to-end deep learning architecture to perform the task of denoising capacitive ECG. The proposed network is trained using motion corrupted three channel cECG and a reference LEAD I ECG collected on individuals while driving a car. Further, we also propose a novel joint loss function to apply loss on both signal and frequency domain. We conduct extensive rhythmic analysis on the model predictions and the ground truth. We further evaluate the signal denoising using Mean Square Error(MSE) and Cross Correlation between model predictions and ground truth. We report MSE of 0.167 and Cross Correlation of 0.476. The reported results highlight the feasibility of performing morphological analysis using the filtered cECG. The proposed approach can allow for continuous and comprehensive monitoring of the individuals in free living conditions.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/1903.12536/full.md

## Figures

2 figures with captions in the complete paper: https://tomesphere.com/paper/1903.12536/full.md

## References

24 references — full list in the complete paper: https://tomesphere.com/paper/1903.12536/full.md

---
Source: https://tomesphere.com/paper/1903.12536