Qualitative assessment of tear dynamics with fluorescein profilometry
Izabela K. Garaszczuk, D. Robert Iskander

TL;DR
This study introduces a new fluorescein profilometry method to qualitatively assess tear film dynamics by measuring fluorescein decay, showing correlations with clinical measures and demonstrating high subject variability.
Contribution
The paper presents a novel fluorescein profilometry technique for tear film assessment and evaluates its repeatability and relationship with clinical parameters.
Findings
TFWR correlates with McMQ score and FTBUT.
Method shows high subject variability with repeatability around 28%.
No significant correlation between TFWR and age or blinking.
Abstract
Purpose: To describe a new methodology for tear-film dynamics assessment by observing fluorescein decay rate over time and to understand the relationship between the newly defined tear fluorescein washout rate (TFWR)and other measures of the tear film behaviour. Methods: Forty subjects (24F/16M) aged (mean +/- standard deviation) 31.8 +/- 14.2 years volunteered for the study. It consisted of the review of medical history, McMonnies questionnaire (McMQ), slit lamp examination, and TFWR using a newly-developed fluorescein profilometry. The repeatability of TFWR measurements was assessed. TFWR estimates were contrasted against patient age, McMQ score, daytime, fluorescein tear film breakup time (FTBUT), tear meniscus height (TMH) and blink frequency. Results: Mean repeatability of the method was 28.13 +/- 9.59%. The group mean TFWR was 39 +/- 23% at 30-s mark after the beginning of…
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.