# Context-aware Monitoring in Robotic Surgery

**Authors:** Mohammad Samin Yasar, David Evans, Homa Alemzadeh

arXiv: 1901.09802 · 2019-01-29

## TL;DR

This paper introduces a context-aware safety monitoring system for robotic surgery that segments tasks and applies specific safety constraints, potentially preventing adverse events by detecting violations early.

## Contribution

The study demonstrates that safety constraints are consistent across different demonstrations and can be used to predict and mitigate unsafe events in robotic surgery.

## Key findings

- Safety constraints are consistent across multiple demonstrations.
- Violations of safety constraints often precede unsafe events.
- Early detection allows for corrective actions before critical failures.

## Abstract

Robotic-assisted minimally invasive surgery (MIS) has enabled procedures with increased precision and dexterity, but surgical robots are still open loop and require surgeons to work with a tele-operation console providing only limited visual feedback. In this setting, mechanical failures, software faults, or human errors might lead to adverse events resulting in patient complications or fatalities. We argue that impending adverse events could be detected and mitigated by applying context-specific safety constraints on the motions of the robot. We present a context-aware safety monitoring system which segments a surgical task into subtasks using kinematics data and monitors safety constraints specific to each subtask. To test our hypothesis about context specificity of safety constraints, we analyze recorded demonstrations of dry-lab surgical tasks collected from the JIGSAWS database as well as from experiments we conducted on a Raven II surgical robot. Analysis of the trajectory data shows that each subtask of a given surgical procedure has consistent safety constraints across multiple demonstrations by different subjects. Our preliminary results show that violations of these safety constraints lead to unsafe events, and there is often sufficient time between the constraint violation and the safety-critical event to allow for a corrective action.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/1901.09802/full.md

## Figures

15 figures with captions in the complete paper: https://tomesphere.com/paper/1901.09802/full.md

## References

21 references — full list in the complete paper: https://tomesphere.com/paper/1901.09802/full.md

---