Robust and accurate electric field sensing with solid state spin ensembles
Julia Michl, Jakob Steiner, Andrej Denisenko, Andre Buelau, Andre, Zimmermann, Kazuo Nakamura, Hitoshi Sumiya, Shinobu Onoda, Philipp Neumann,, Junichi Isoya, and Joerg Wrachtrup

TL;DR
This paper demonstrates a highly sensitive method for measuring macroscopic AC electric fields using ensembles of NV center spins in diamond, achieving nanotesla-level precision at room temperature.
Contribution
It introduces a novel approach combining classical lock-in detection with quantum phase estimation to enhance electric field measurement sensitivity with solid state spin ensembles.
Findings
Achieved electric field sensitivity down to 10^{-7} V/μm.
Demonstrated effective suppression of technical noise.
Enabled $t^{-1/2}$ uncertainty scaling over extended periods.
Abstract
Electron spins in solids constitute remarkable quantum sensors. Individual defect centers in diamond were used to detect individual nuclear spins with nanometer scale resolution, and ensemble magnetometers rival SQUID and vapor cell magnetometers when taking into account room temperature operation and size. NV center spins can also detect electric field vectors, despite their weak coupling to electric fields. %even that of an isolated fundamental charge, despite their weak coupling to electric fields. Here, we employ ensembles of NV center spins to measure macroscopic AC electric vector fields with high precision. We utilize low strain, C enriched diamond to achieve maximum sensitivity and tailor the spin Hamiltonian via proper magnetic field adjustment to map out the AC electric field strength and polarization and arrive at refined electric field coupling constants. For high…
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Robust and accurate electric field sensing with solid state spin ensembles
Julia Michl
Jakob Steiner
Andrej Denisenko
- Physikalisches Institut, University of Stuttgart, Pfaffenwaldring 57, 70569 Stuttgart, Germany
André Bülau
Hahn-Schickard, Allmandring 9b, 70569 Stuttgart, Germany
André Zimmermann
Institut für Mikrointegration, University of Stuttgart, Allmandring 9b, 70569 Stuttgart, Germany
Kazuo Nakamura
Application Technology Research Institute, Tokyo Gas Company, Ltd., Yokohama, 230-0045 Japan
Hitoshi Sumiya
Advanced Materials Laboratory, Sumitomo Electric Industries, Ltd., Itami, 664-0016 Japan
Shinobu Onoda
Takasaki Advanced Radiation Research Institute, National Institutes for Quantum and Radiological Science and Technology, Takasaki, 370-1292, Japan
Philipp Neumann
- Physikalisches Institut, University of Stuttgart, Pfaffenwaldring 57, 70569 Stuttgart, Germany
Junichi Isoya
Faculty of Pure and Applied Sciences, University of Tsukuba, Tsukuba, 305-8573 Japan
Jörg Wrachtrup
- Physikalisches Institut, University of Stuttgart, Pfaffenwaldring 57, 70569 Stuttgart, Germany
Abstract
Electron spins in solids constitute remarkable quantum sensors. Individual defect centers in diamond were used to detect individual nuclear spins with nanometer scale resolution, and ensemble magnetometers rival SQUID and vapor cell magnetometers when taking into account room temperature operation and size. NV center spins can also detect electric field vectors, despite their weak coupling to electric fields. Here, we employ ensembles of NV center spins to measure macroscopic AC electric vector fields with high precision. We utilize low strain, 12C enriched diamond to achieve maximum sensitivity and tailor the spin Hamiltonian via proper magnetic field adjustment to map out the AC electric field strength and polarization and arrive at refined electric field coupling constants. For high precision measurements we combine classical lock-in detection with aspects from quantum phase estimation for effective suppression of technical noise. Eventually, this enables uncertainty scaling of the electric field strength over extended averaging periods, enabling us to reach a sensitivity down to V/µm.
Solid state spins have matured to leading contenders in the field of nanoscale sensing 1. As spins couple to magnetic fields via their magnetic moment, they naturally lend themselves to magnetometry. Additionally, by coupling to the lattice they have been shown to measure temperature and strain, and hence force or pressure with high sensitivity and exquisite spatial resolution2. Intrinsically however, spins only interact with electric fields via the orbital angular momentum of e.g. electrons. Yet, precision sensing of electric fields or charges is a long standing challenge in metrology, tackled by e.g. single electron transistors 3, 4, 5, energy level shift measurements of ions 6 or Rydberg atoms7. Spins with total angular momentum couple to gradients of electric fields and all spins can be indirectly affected by electric fields via spin orbit coupling. It would thus be interesting to extend those studies to solid state spin systems for the sake of precision metrology especially with high spatial resolution. Electric field coupling to spins has been observed in a variety of cases8, 9 and used e.g. for their coherent control. Point defects in diamond10, 11 and e.g. SiC12 typically show little coupling to electric fields because of the small spin orbit coupling in these materials and the fact that the orbital angular momentum is largely quenched at room temperature. However, the NV center shows a sizeable spin orbit coupling in the excited state and a small fraction of that is measured in the electron ground state. This shift has been detected before using single NVs and in NV ensembles with strong fields, using ESR and ODMR9, 13, 14. In the present work we are concerned with precision measurements of weak AC electric fields using a low strain, isotopically engineered HPHT diamond. As the NV center in diamond has a symmetry, the linear Stark shift Hamiltonian is given by8
[TABLE]
with the axial coupling constant being around 3.5 kHz/V/µm and the transversal coupling being around 170 kHz/V/µm. The first term is suppressed by the zero-field splitting and the last term is, due to its small coupling constant , not viable for precision measurement. Hence the transversal term, given by is of primary importance for this work.
Under standard sensing conditions, the spin of the NV center in the ground state is dominated by the zero-field splitting , followed by the axial magnetic field . The resulting eigenstates are thus the eigenstates of the operator, noted as , and . The energies of these states do not change in first order with an applied electric field, which can be seen best by rewriting the transversal term of the Stark shift Hamiltonian to
[TABLE]
with the transversal electric field strength and the angle of the electric field in the -plane . The expectation value of in the basis of is zero:
[TABLE]
Therefore, to measure a linear Stark shift using NVs, the eigenstates of the NV have to be designed to be susceptible to electric fields. Such an eigenbasis can be achieved by three means, applying an electric field strong enough to couple stronger to the NV than the axial magnetic field13, having no magnetic field at all, or applying a transversal magnetic field15, 9, 16. The first two options are achievable, but technically difficult. Applying a transversal magnetic field on the order of some millitesla leads to a suppression of the coupling to an axial magnetic field. States dominated by a transversal magnetic field are insensitive towards fluctuating surrounding nuclear spins and exhibit longer coherence times. These states, without an axial magnetic field and a transversal magnetic field much smaller than the zero-field splitting, are
[TABLE]
where is the azimuthal angle of the magnetic field and they show a linear Stark shift, as the expectation values of in this basis become
[TABLE]
This shows that the shift depends significantly on the direction of the transversal electric and magnetic fields relative to each other and to the direction of the three carbon atoms adjacent to the vacancy16. In this Hamiltonian, is defined as being along the projection of one of the vacancy-carbon axes on the transversal plane. For the lower transition, the shift is positive at , where both fields are in the direction of a carbon atom. Hence, the shift follows the three-fold symmetry of the NV, as leads to a shift proportional to 15. In an ensemble of NVs, the directions of the NVs are statistically distributed, so along each of the four possible alignment axes for the NV, the order of nitrogen and vacancy is reversed for half of the NVs, as shown in fig. 1(a). It follows, that for a given applied magnetic and electric transversal field, the frequency shift is positive for half the NVs in the ensemble and negative for the other half of the ensemble. So, only the absolute value of the shift is measurable. A dense ensemble of NVs also exhibits high strain, which is distributed randomly between the NVs, leading to a broadening of the transition. As the strain Hamiltonian has the same form as the electric field Hamiltonian, a static electric field can not be distinguished from strain and the transitions sensitive to electric fields are inhomogeneously broadened by strain far more than the states dominated by an axial field.
Here we measure the AC electric field of a plate capacitor using a 500 µm large diamond with a 0.9 ppm NV ensemble, see fig. 1. We apply a static magnetic field to taylor the NV spin Hamiltonian as mentioned and use microwave fields to manipulate the spins and perform measurement sequences. The spin states are read out optically through the spin-dependent fluorescence of the NV by applying laser pulses on the ensemble where the resulting PL signal accumulates the response of the NV spins within a sample volume of 500x50x50 µm3 in a single sweep. Conventional metrology involving NVs depends on repetitive measurement schemes where the signal to be measured is triggered to the measurement sequence and the results are averaged.17. The use of a Hahn-Echo measurement, as shown in fig. 2(a), leads to a phase collected by the NV spin during the free evolution time (see fig. 2(b)), which is maximum for being equal to the period of the signal. The scheme measures the cosine of the accumulated phase ,
[TABLE]
with the electric field amplitude , the signal frequency and the evolution time . The resulting PL signal response is hence also a cosine which decays for higher electric fields due to electric and magnetic field inhomogenities over the measured NV ensemble. This signal over the applied voltage amplitude is shown in fig. 2 (c). Here, the most sensitive point for electric fields is at an applied voltage amplitude of about 4.8 V, where the slope is steepest (see fig. 2(c)). Especially for small electric field signals, the measurement of the sine of the accumulated phase would be advantageous, yet is not possible here since the sign of the frequency shift is reversed for half of the NVs, as mentioned before. By measuring the noise of the measurement, the Allan deviation can be calculated (see fig. 2 (d)) and it can be seen that it scales only up to a few tens of ms, leading to a maximum precision of about 3.1 V/µm. The maximum phase which can be collected during such a measurement is limited by the electron spin coherence time . This time can be prolonged by using advanced dynamical decoupling sequences, e.g. CPMG or XY-8. The sensitivity then scales with , when is the apparent coherence time under pulsed decoupling. Typically is significantly longer than 1. In a quasiclassical picture, the multipulse sequences generate a filter function to suppress noise which is the Fourier transform of the pulse sequence applied. The periodic signal to be measured exactly falls into the transmission window of this filter function, while all noise components outside this transmission window are suppressed. For a dynamical decoupling sequence like CPMG, the width of this spectral window scales with when is the overall phase accumulation length and the suppression of noise outside of this spectral window goes with , when is the number of decoupling pulses. Both and are limited by the coherence time of the defect () and the achievable Rabi frequency. As a result the width of the spectral window is essentially limited by the spin properties. All noise components falling within this spectral window will contribute to the signal-to-noise ratio of the measurement. The influence of laser noise on the measurement is also limited by referencing the measurement signal to the simultaneously measured laser power. The Allan deviation plot shown in fig. 2(c) shows that sensitivity only scales as the standard quantum limit up to averaging times of around a few 10 ms. After that low frequency noise components deteriorate further scaling of the precision of the measurement. It is thus of central importance to identify methods which further allow to reduce the spectral width of the filter function to achieve improved suppression particularly of low frequency noise components.
Recently, several works extended the dynamical decoupling scheme for the measurement of periodically oscillating, phase stable signals18, 19, 20. In these schemes the signal acquired by dynamical decoupling sequences is accumulated in a phase coherent manner. By this the filter function of the pulse sequence are further narrowed beyond the value limited by spin relaxation. Ideally, its width is only limited by the total measurement time of the experiment. Previously, this was used for precise measurement of the signal frequencies, as the frequency resolution as well as the bandwidth is not limited by the coherence times of the NV but by the coherence time of the signal. Here, we show the usage of this measurement scheme to measure signal amplitudes with enhanced precision. The main idea is as follows. An AC signal can be measured effectively using a Hahn-Echo measurement, as long as the frequency of the signal is not lower than . The -pulse in the middle of the free evolution time refocuses the spin such that any low frequency fluctuations are averaged out, while an AC signal which changes its sign during the -pulse is enhanced. The phase between measurement and signal is now shifted between subsequent measurements, as the measurement train adds a phase shift of towards the signal after each measurement, with being the signal frequency and the time added between measurement sequences. The phase collected by the NV is now dependent on the phase of the measured signal compared to the measurement (see fig. 3 and Supporting Information):
[TABLE]
where is the amplitude of the frequency shift of the respective NV spin transition caused by the signal and is the phase of the signal at the start of the -th measurement. The maximum accumulated phase is collected when the signal is a sine during the Hahn-Echo measurement, as shown in fig. 3 (left). As seen in eq. 9, the accumulated phase goes linear with the shift and oscillates with the signal frequency . The accumulated phase cannot be read out directly, instead either its sine or cosine is retrieved. When the sine of the phase is measured, and the shift is small, the measured signal can be approximated by , resulting in an oscillation at frequency and an amplitude proportional to 18. For larger shifts or measurements of the cosine, this linear approximation does not hold and oscillations at multiples of appear in the measured signal. A measurement of the cosine of the phase, as done in this work, is not suitable for weak signals, as it does not show this linear behavior. The measured signal in this case goes with
[TABLE]
where is a Bessel function of the first kind. A detailed calculation of the relation is shown in the Supporting Information. An example from such a measurement can be seen in fig. 4(a). Eq. 10 shows, that the resulting spectrum exhibits peaks at multiples of . With a higher signal strength, higher orders of these Fourier components will appear21. The bandwidth of the measurement with respect to the coupling strength is limited only by the chosen phase difference . As this scheme measures phases between [math] and , it is an effective way to circumvent any ambiguity coming from measuring the cosine of the accumulated phase, i.e. the signal for being the same as for 22. In fig. 4(b) the amplitudes for the different Fourier components are shown over the coupling to the applied electric field. Fig. 4 (d) shows the scaling of the sensitivity over measurement time. The scaling is extended by four orders of magnitude in comparison to conventional Hahn-Echo measurement shown in fig. 2(d) as this scheme works in a comparable way to a classical lock-in detection, where all noise away from the signal frequency and its multiples does not affect the measurement. Here, the limit of the achieved sensitivity is the signal coherence, shown by the difference between the scaling with and without applied signal in fig. 4(d). By comparing the amplitudes of different Fourier components, the influence of the contrast can be limited. As the contrast of the measurement can change over time (e.g. by temperature shifts leading to different Rabi frequencies or by microwave power fluctuations), this further improves the scaling of the measurement, which is shown in fig. 4(d) by the difference between the blue and the purple curve.
A comparison of the measured coupling strength and the independently verified applied voltage amplitudes lead to a measured shift of the NV transition frequencies of 0.315 kHz/V, which can be recalculated using the gap of the plate capacitor as µm to get the coupling constant kHz/V/µm, refining the value given by van Oort14 of kHz/V/µm. A detailed calculation of this coupling constant can be found in the Supporting Information.
Alternatively to the transition to , the Stark shift can also be measured in the double quantum transition (DQT) between the two states. For this transition, the frequency shift is doubled, as the two states experience identical shifts but with a different sign. The resulting measurement is shown in fig. 5 (a). Due to differences in the transition frequency and microwave coupling in an ensemble, MW pulses will not only excite a double quantum transition, but additionally the single quantum transition (SQT) is visible in the measurement. As the percentage of SQT in the measurement does not depend on the electric field, it is assumed to be constant over all measurements using the same MW pulses. In addition to the advantage of measuring twice the phase, making it possible to measure smaller signals, a DQT measurement also allows for the elimination of temperature influences during a measurement, as both transitions are shifted equally by temperature. The measurement presented here in fig. 5 shows the advantage for low signal strength over a SQT measurement. Yet, the electric field sensitivity showed no improvement, meaning either that there is no limiting noise from temperature or the imperfect MW pulses and residual SQT make this advantage void. Here, robust MW pulses and two orthogonal linear polarized MW fields could help in the future to achieve a much higher degree of population in the double quantum transition, making it possible to fully utilize the advantages of a DQT measurement.
In conclusion, we presented precision measurement of electric fields using an ensemble of NV centers. The measurement of AC electric fields much smaller than the intrinsic strain could be shown. We achieved a precision of approximately V/µm/. For this, we adapted continuous measurement schemes and operate them in the non-linear regime. This allows for the measurement of signals over a large bandwidth of signal frequencies and also a large bandwidth of coupling frequencies, akin to a quantum phase estimation algorithm22. As we compare the amplitudes at multiples of the known signal frequency, this measurement also functions as a lock-in detection. The coupling constant for a coupling between NV and electric field was found to be kHz/V/µm, which is in good agreement with the previously reported coupling constant kHz/V/µm14. The longitudinal coupling constant was too small to be measured, which would match with a coupling constant kHz/V/µm reported by Van Oort. With measurements at the ground state level anti-crossing, we are able to give an upper limit for the as of yet unmeasured coupling constant (see Supporting Information). Our measurement scheme might well be extended to other sensing modalities where weak signals are accumulated over extended averaging period including magnetic field and temperature measurements.
1 Acknowledgments
We want to thank Ingmar Jakobi and Tetyana Shalomayeva for their support with the experiments. Furthermore, we acknowledge the valuable input by Marcus Doherty, especially with regards to the measurement of the constant. We acknowledge the support of the European Commission Marie Curie ETN “QuSCo” (GA N°765267), and the German science foundation (SPP 1601). This work was also supported by ERC grant SMel, the Max Planck Society and the Humboldt Foundation and the EU - FET Flagship on Quantum Technologies through the Project ASTERIQS. In addition, we acknowlegde the support of the Japan Society of the Promotion of Science (JSPS) KAKENHI (No. 17H02751).
2 Author contributions
JM, JS, AD and PN carried out the experiments. AB and AZ gave technical support for the experiments. KN, HS, SO and JI synthesized and characterized the diamond sample. JW supervised the research work. All authors contributed to preparation of the manuscript.
3 Competing financial interests
All authors declare not to have any competing financial interests.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1Degen et al. 2017 Degen, C. L.; Reinhard, F.; Cappellaro, P. Quantum sensing. Reviews of Modern Physics 2017 , 89 , 1–39
- 2Laraoui et al. 2015 Laraoui, A.; Aycock-Rizzo, H.; Gao, Y.; Lu, X.; Riedo, E.; Meriles, C. A. Imaging thermal conductivity with nanoscale resolution using a scanning spin probe. Nature Communications 2015 , 6
- 3Lee et al. 2008 Lee, J.; Zhu, Y.; Seshia, A. Room temperature electrometry with SUB-10 electron charge resolution. Journal of Micromechanics and Microengineering 2008 , 18 , 025033
- 4Vincent et al. 2004 Vincent, J. K.; Narayan, V.; Pettersson, H.; Willander, M.; Jeppson, K.; Bengtsson, L. Theory of a room-temperature silicon quantum dot device as a sensitive electrometer. Journal of Applied Physics 2004 , 95 , 323–326
- 5Neumann et al. 2013 Neumann, C.; Volk, C.; Engels, S.; Stampfer, C. Graphene-based charge sensors. Nanotechnology 2013 , 24 , 444001
- 6Osterwalder and Merkt 1999 Osterwalder, A.; Merkt, F. Using high rydberg states as electric field sensors. Physical Review Letters 1999 , 82 , 1831–1834
- 7Sedlacek et al. 2012 Sedlacek, J. A.; Schwettmann, A.; Kübler, H.; Löw, R.; Pfau, T.; Shaffer, J. P. Microwave electrometry with Rydberg atoms in a vapour cell using bright atomic resonances. Nature Physics 2012 , 8 , 819–824
- 8Mims 1976 Mims, W. The linear electric field effect in paramagnetic resonance ; Clarendon Press, 1976