Comment on "Tunable Supermode Dielectric Resonators for Axion Dark-Matter Haloscopes"
Jinsu Kim, SungWoo Youn, Junu Jeong, and Yannis K. Semertzidis

TL;DR
This paper critiques a proposed dielectric resonator tuning scheme for axion dark-matter searches, arguing that previous claims of significant sensitivity improvements are based on unrealistic models and inappropriate figures of merit.
Contribution
It provides a reassessment of the proposed tuning scheme using realistic cavity models and proper figures of merit, showing the claimed benefits are not as substantial as initially suggested.
Findings
Previous sensitivity improvements are overstated due to unrealistic modeling.
Proper analysis reduces the perceived advantage of the tuning scheme.
The scheme's practical benefits are less significant than originally claimed.
Abstract
We comment on a recently published paper, Phys. Rev. Applied 9, 014028 (2018), which presents frequency-tuning mechanisms for dielectric resonators and demonstrates their potential application to axion haloscopes. One of the schemes introduces a cylindrical dielectric hollow and splits it in the axial direction to tune the frequency. The authors claim that this scheme offers a 1 to 2-order-of-magnitude improvement in axion search sensitivity in exploiting a higher-order resonant mode. We find that their study is based on unrealistic cavity modeling and inappropriate choice of the figure of merit (FOM), which could mislead to the significant improvement in sensitivity. Considering a practical cavity structure and an appropriate FOM, we recalculate the significance of the scheme, which turns out to be not substantial.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsPhysics of Superconductivity and Magnetism · Superconducting and THz Device Technology · Cold Atom Physics and Bose-Einstein Condensates
Comment on “Tunable Supermode Dielectric Resonators for Axion Dark-Matter Haloscopes”
Jinsu Kim
Department of physics, KAIST, Daejeon 34141 Republic of Korea
SungWoo Youn
Center for Axion and Precision Physics Research, IBS, Daejeon 34051 Republic of Korea
Junu Jeong
Department of physics, KAIST, Daejeon 34141 Republic of Korea
Yannis K. Semertzidis
Department of physics, KAIST, Daejeon 34141 Republic of Korea
Center for Axion and Precision Physics Research, IBS, Daejeon 34051 Republic of Korea
We comment on a recently published paper bib:report , which presents frequency-tuning mechanisms for dielectric resonators and demonstrates their potential application to axion haloscopes. One of the schemes introduces a cylindrical dielectric hollow and splits it in the axial direction to tune the frequency. The authors claim that this scheme offers a 1 to 2-order-of-magnitude improvement in axion search sensitivity in exploiting a higher-order resonant mode. We find that their study is based on unrealistic cavity modeling and inappropriate choice of the figure of merit (FOM), which could mislead to the significant improvement in sensitivity. Considering a practical cavity structure and an appropriate FOM, we recalculate the significance of the scheme, which turns out to be not substantial.
It is noted that the cavity in their simulation study is not realistically modeled to accommodate the tuning mechanism that they pursue in the paper. For the realistic cavity design, the proposed tuning mechanism inevitably requires circular hollow holes on both the top and bottom end-caps of the resonator, through which a significant field leakage can be induced for transverse-magnetic modes. Due to this, the calculated improvement in axion sensitivity could be overestimated. Furthermore, we also notice that a reasonable axion sensitivity is not estimated because of their choice of the FOM, where the geometry factor () was chosen rather than the quality factor (). A geometry factor, defined in the paper as
[TABLE]
describes surface loss and is consistent with the quality factor only for closed geometries. A quality factor, on the other hand, reflects other effects, such as field leakage and external interference, in the form of
[TABLE]
and works for generic geometries. Hereby, we repeat the calculations using a qualtity-factor-based FOM, , which is appropriate for axion search sensitivity.
A simulation study is performed employing the same simulation software, cavity modeling, and dielectric material as those in the paper. Using the FOM based on the geometry factor, we obtain the consistent results with those described in Fig. 9 of the paper, which convinces that we understand their scheme. In the same configuration, we repeat the calculation using the FOM based on the quality factor. Now a realistic cavity design is considered by introducing a circular hollow gap on both the top and bottom end-caps of the resonator. In order to see the effect of depth of the hollow gaps, two thicknesses of the end-caps are considered - 10 mm and 50 mm. Scattering boundary conditions are applied for non-metallic surfaces. The results show that the realistic cavity design undergoes substantial reduction in FOM comparing to that for the unrealistic design described in the paper, as can be seen in Fig. 1, and that the improvement is not as significant as it was claimed. It is seen that the main effect comes from a significant drop in quality factor, as shown in Fig. 1. There are also some indications that mode mixings may take place over the process of the frequency tuning.
In summary, we review the tuning mechanism for dielectric ring resonators proposed in Ref. bib:report and recalculate the sensitivity by considering a practical cavity design and an appropriate FOM. The results reveal that the improvement in axion sensitivity is not as substantial as claimed in the paper.
This work was supported by IBS-R017-D1-2018-a00/IBS-R017-Y1-2018-a00.
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1(1) B. T. Mc Allister et al. , “Tunable Supermode Dielectric Resonators for Axion Dark-Matter Haloscopes”, Phys. Rev. Applied 9 , 014028 (2018).
