MWPC prototyping and performance test for the STAR inner TPC upgrade
Fuwang Shen, Shuai Wang, Fangang Kong, Shiwei Bai, Changyu Li,, Flemming Videbaek, Zhangbu Xu, Chengguang Zhu, Qinghua Xu, Chi Yang

TL;DR
This paper reports on the development and testing of a new MWPC prototype for the STAR inner TPC upgrade, demonstrating it meets all performance specifications through X-ray testing.
Contribution
The paper introduces a new MWPC prototype with improved wire tension and pitch precision, and verifies its performance for the STAR iTPC upgrade.
Findings
Wire tension precision better than 6%
Gas gain uniformity better than 1% RMS
Energy resolution better than 20% FWHM
Abstract
A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6 and wire pitch precision better than 10 m. The gas gain uniformity and energy resolution are measured to be better than 1 (RMS) and 20 (FWHM), respectively, using an Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. The test results show that the constructed iTPC prototype meets all project requirements.