A new precision measurement of the {\alpha}-decay half-life of 190Pt
Mih\'ay Braun (1), Yordan M. Georgiev (2), Tommy Sch\"onherr (2),, Heinrich Wilsenach (3), Kai Zuber (3) ((1) Institute for Nuclear Research of, the Hungarian Academy of Sciences (2) Institute of Ion Beam Physics and

TL;DR
This study presents a precise laboratory measurement of the alpha-decay half-life of 190Pt, achieving a 3.2% uncertainty, which aligns well with previous geological estimates.
Contribution
The paper provides a new, highly accurate laboratory measurement of 190Pt's alpha-decay half-life using a low background ionisation chamber, improving precision over prior estimates.
Findings
Half-life of 190Pt measured as (4.97±0.16)×10^11 years
Measurement uncertainty reduced to 3.2%
Results agree with geological comparison methods
Abstract
A laboratory measurement of the -decay half-life of Pt has been performed using a low background Frisch grid ionisation chamber. A total amount of 216.60(17) mg of natural platinum has been measured for 75.9 days. The resulting half-life is years, with a total uncertainty of 3.2%. This number is in good agreement with the half-life obtained using the geological comparison method.
| Target Name | Mass [mg] | Thickness [nm] |
|---|---|---|
| Pt01 | 75.2(1) | 441(4) |
| Pt02 | 73.1(1) | 429(4) |
| Pt03 | 68.3(1) | 401(4) |
| Nucleon | Abundance | Lit. Abundance |
|---|---|---|
| Number | [%] | [%] |
| 190 | 0.01125(21) | 0.014(1) |
| 192 | 0.785(26) | 0.782(7) |
| 194 | 33.23(35) | 32.967(99) |
| 195 | 33.33(13) | 33.832(10) |
| 196 | 25.20(42) | 25.242(41) |
| 198 | 7.4625(90) | 7.163(55) |
| Quantity | Value | Relative Error | |
|---|---|---|---|
| [%] | |||
| Detector Eff. | [%] | 98.6(2.2) | 2.23 |
| 190Pt Abundance | [%] | 0.01125(21) | 1.88 |
| Signal Rate | [c.p.d] | 133.1(13) | 1.00 |
| Molar Mass | [g/mole] | 195.1(11) | 0.57 |
| Geometric Eff. | [%] | 47.014(53) | 0.11 |
| Background Rate | [c.p.d] | 1.0203(89) | 0.087 |
| Total Mass | [mg] | 216.60(17) | 0.08 |
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
A new precision measurement of the -decay half-life of 190Pt
Mihály Braun
Institute for Nuclear Research of the Hungarian Academy of Sciences, Bem tér 18, Debrecen, 4026 Hungary
Yordan M. Georgiev
Tommy Schönherr
Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden, Germany
Heinrich Wilsenach
Kai Zuber
Institut für Kern- und Teilchenphysik, Technische Universität Dresden,01069 Dresden, Germany
Abstract
A laboratory measurement of the -decay half-life of 190Pt has been performed using a low background Frisch grid ionisation chamber. A total amount of 216.60(17) mg of natural platinum has been measured for 75.9 days. The resulting half-life is years, with a total uncertainty of 3.2%. This number is in good agreement with the half-life obtained using the geological comparison method.
keywords:
Alpha decay; Natural radioactivity; 190Pt isotope; Pt-Os dating system;
PACS:
23.60.+e; 29.40.Cs; 27.80.+w;
††journal: Nuclear Physics B
1 Introduction
The study of -decays has been important for the understanding of nuclei and their properties for more than a century. Currently these studies still have impact in various areas of nuclear physics, providing information which is valuable and often not accessible otherwise. The relation between the half-life and the Q-value of the transition has been established long ago as the Geiger-Nuttall law [1]. The Geiger-Nuttall law is generally accepted and has been improved by the Viola-Seaborg parametrisation [2]. Furthermore, empirical relations were established for a description beyond the Geiger-Nuttall law [3, 4]. Providing more accurate input data for these studies is always helpful.
Another important application is the usage of 190Pt as cosmochronometer as suggested by [5]. Studying terrestrial samples well known from U-Pb dating a value has been derived for the decay constant of 190Pt of per year , later corrected by [6] with an error of 1% to be per year. Newer measurements in 2004 [7] on iron meteorites came to a result of per year with a similar uncertainty. Hence both results are not in very good agreement with each other and might indicate a systematic error of about 5%. Hence an independent laboratory measurement of the 190Pt half-life of less than 5% would shed new light on the obtained values.
The 190Pt-186Os system is a powerful tool to investigate the chronology and evolution of geo- and cosmo-chemistry samples. For example, it can be used to understand the history of the abundances of highly siderophile elements in the Earth’s mantle. By exploiting the fact that platinum can separate from osmium during partial melting in the mantle, [8] derived that the abundances of these elements were contributed by a late veneer. Furthermore, the age of iron meteorites can also be derived thanks to the different distribution coefficients of Pt and Os during crystallisation [7].
Three different methods have been used over almost 90 years to derive a half-life determination of 190Pt : First of all laboratory experiments based on ionisation chambers and nuclear emulsions using the energy-range relation for -particles. Secondly, geochemical samples from the aforementioned dating of the early solar system and earth and finally semi-empirical calculations. All the experimental results so for have been compiled in [9]. In this reference weighted averages are given of years (laboratory measurements), years (geological measurements) and years (semi-empirical approach) respectively. While laboratory and semi-empirical data show more than 10% uncertainty, even so individual results show a significantly wider spread, the claimed geological uncertainties are on the level of 1% and below. Furthermore there is a significant difference among the weighted averages of all three values, so it is not really clear what the half-life of 190Pt is. In addition the recommended value by the Nuclear Data sheets is years [10].
The aim of this paper is to provide new data about the half-life of the 190Pt-decay by performing a laboratory measurement with a precision significantly below 10%. For that purpose a low background ionisation chamber has been used. The Q-value of the decay is 3252(6) keV [11], this corresponds to a peak in the -spectrum at = 3183(6) keV.
2 Experimental Setup
The -decay of was measured with the use of a twin Frisch-grid ionisation chamber (TFGIC), with a common anode in the middle, an upper chamber usable as a veto and monitor and a lower chamber for the real measurement. Its diameter is 30 cm and all samples are placed on the bottom. The chamber was specifically designed for the detection of low rate -decays. This was achieved through constructing a TFGIC with a low level of internal radioactive impurities and in adding pulse shape discrimination to separate background from signal. In this way FADC pulses were taken from the grid and from the anode. This allowed to identify cuts and reject non-physical events. As chamber gas P10 was used. The chamber has a background of only 22 counts in the energy region of 1 MeV to 3.5 MeV within a 30.8 day run period. The majority of the events were above 5 MeV as the events originate from Rn-decay products due to the sample changing process and a tiny leak. The design of the chamber and its performance is discussed in more detail in [12].
3 Measurement
Natural platinum was deposited on three 4” silicon wafers by electron beam evaporation in a LAB 500 evaporation system (Leybold Optics GmbH). The following parameters were used during deposition: 1.3 kW beam power, 0.6 nm/s deposition rate, 300 mm distance between the crucible and the wafer, and Pa initial chamber pressure. To optimise the detection of the -decay from 190Pt, the coating was produced in the range of 400 nm. The wafers were weighed before and after deposition to determine the amount of platinum deposited. Assuming a density of 21.45(5) g/cm3, it is possible to estimate the thickness of the deposited layers. This is shown in table 1. The platinum was obtained from Kurt J. Lesker*®* and had a purity of 99.99%.
The three wafers were placed at the bottom of the chamber. They were arranged so that their centres formed a triangle without overlapping. This configuration was chosen so that most of the platinum is close to the centre of the chamber. In this way tiny changes in the detection efficiency close to the side walls can be ignored. Nevertheless, the effect was taken into account in the simulation.
The total measurement time was 75.9 days. The run was started and was only interrupted to renew the counting gas, while the position was not altered and the chamber was not opened. This was done four times to ensure the most stable run conditions. Moreover, this also ensured that the background was reduced as a function of run time, leading to a cleaner run. All of the periods between the flushes were initially treated as separate runs. The rate and energy spectra were then compared to ensure that the run technique was reliable. After this, all of the data was combined.
The isotopic abundance was measured at Debrecen, Hungary, using inductively coupled plasma mass spectrometry (ICP-MS), the values of which are given in Table 2. The molar mass is calculated from the abundances. This was done by multiplying each abundance with its corresponding mass, and summing the products. The masses of each isotope were taken from [13]. This results in a molar mass of 195.1(11) g/mole. The abundances were measured and compared with a calibration standard of natural platinum obtained from IRMM (Geel).
In the measurement there was a small contamination into the 190Pt signal region from the tailing of background -lines at higher energy. This contamination was fitted with an exponential and the rate was found to be 1.0203(89) c.p.d in the region of interest (ROI). The ROI extends from 1.5 MeV to 3.7 MeV. This was compared with the background rate in the ROI measured in a background run of 37 days. The rate was found to be 1.10(17) c.p.d., which agrees well with the background taken from the fit.
The fit of the energy spectrum around the 190Pt peak region can be seen in Figure 1. The signal of the -decay was then fitted with the characteristic spectrum [14] using the least squared method. The fit gave a reduced of 110/71 = 1.55, and the fit parameters were unconstrained. The slight tension in the fit comes from the peak of the distribution. The fitting function assumed that the energy broadening in the spectrum due to self ionisation is less than the energy resolution. For samples of about 400 nm thickness, a gaussian peak can be expected as the energy broadening is much smaller than the energy resolution. Though the fit is still a very good approximation. The total number of counts in the ROI was found to be 10180(101). Subtracting the background from this gives a number of signal events of 10103(101), which corresponds to a 190Pt decay rate of 133.1(13) c.p.d.
To obtain the number of atoms the samples were weighted. The number of atoms is calculated in the following way,
[TABLE]
where is the weighted mass of the platinum, is the molar mass of the natural platinum, is Avogadro’s constant and is the isotopic abundance of . A small number of events are lost due to the inefficiencies of the data cuts and the detection characteristics. This is given as the detection efficiency which was previously measured to be 98.6(22)% [12]. A Monte Carlo simulation was performed using the GEANT simulation package. This was used to determine the efficiency of detecting an -particle considering the geometry of the sample. This was found to be 47.014(52)% as the samples are on the bottom of the chamber. Accounting for these two efficiencies then gives the true rate in the chamber as 287.2(7.0) c.p.d.. The half-life can then be calculated using the following formula,
[TABLE]
where is the true signal rate in the chamber. Following this procedure gives a half-life of the ground state transition of;
[TABLE]
The error here is the combination of the statistical and systematic error added in quadrature. The values used to derive the half-life and the sources of uncertainties can be seen in table 3.
To achieve a “gold standard” relative uncertainty of 0.2% (as in the case of 238U) two very important steps have to be taken. The first is to reduce the uncertainty coming from the sample while still having an adequate activity. This can be achieved for instance by using AMS to select and implant only 190Pt a few nanometers into an ultra clean target material. The number of implantation isotopes should be characterised to a relative uncertainty below 0.1%. Enough of the 190Pt should be implanted to give a reasonable rate in the chamber. To have a statistical uncertainty of around 0.1%, 1,000,000 events need to be seen in the chamber. A rate of 0.3 Bq could reach the desired statistics in a reasonable time. This would take atoms of 190Pt. The second obstacle would be to eliminate the main systematic uncertainty in the chamber, which is the knowledge of the detector efficiency. This would require a calibration source which has an activity known to the precision of 0.1%.
4 Results and Discussions
In this paper we have presented a new half-life of the -decay of 190Pt. The aim with respect to previous laboratory measurements was a much smaller error budget. Hence, this is the first half-life measurement of 190Pt that uses ICP-MS to determine the isotopic abundance. Furthermore the measuring time is about an order of magnitude longer than any other ionisation chamber measurement performed. In this way the counting statistics uncertainty could be reduced to 1%. Finally, due to the design of the chamber being made of low-background materials and the usage of very thin targets events of the peak tailing towards lower energy are a minor correction. The analysis is based on pulse shape discrimination, that has a high efficiency of discriminating between signal and background. The geometric efficiency has also been determined using a complex simulation.
The result of 4.97(16) years is in good agreement with the half-life obtained using the geological comparison method of 4.78(5) years. Figure 2 shows a graph of the half-life measurements of 190Pt as a function of year. It is apparent from this graph that the most recent direct counting method results do not agree well with each other, whereas the most recent half-lives determined using the geological comparison method have been consistent with each other. For the first time it has been shown that the geological comparison method is in good agreement with the direct counting method.
The sources on possible pitfalls of previous direct counting measurements are unclear. It is however apparent that the isotopic abundance was not measured for each half-life determination. It is also interesting to note that the uncertainty from the abundance is not considered. According to “Atomic weights of the elements: Review 2000” [13] the relative variation between different samples is around 7%. When this uncertainty is taken into account, the discrepancy becomes smaller, but it is still statistically relevant. Apart from this oversight, the source of the discrepancy is still unclear. Further direct counting measurements could lead to a statistical basis for adjusting or eliminating discrepant data.
5 Acknowledgements
We would like to thank B. Scheumann from the Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf for the assistance with the platinum deposition. We would also like to thank M. Lugaro for valuable discussions and information. This work was supported by BMBF (02NUK013B).
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1[1] H. Geiger, J. Nuttall, The ranges of the alpha particles from various radioactive substances and a relation between range and period of transformation , Philosophical Magazine Series 6 22 (130) (1911) 613–621. doi:10.1080/14786441008637156 . URL http://dx.doi.org/10.1080/14786441008637156 · doi ↗
- 2[2] B. Sahu, S. Bhoi, Viola-Seaborg relation for α 𝛼 \alpha -decay half-lives: Update and microscopic determination of parameters , Phys. Rev. C 93 (2016) 044301. doi:10.1103/Phys Rev C.93.044301 . URL http://link.aps.org/doi/10.1103/Phys Rev C.93.044301 · doi ↗
- 3[3] V. Y. Denisov, A. A. Khudenko, alpha-decay half-lives: Empirical relations , Phys. Rev. C 79 (2009) 054614. doi:10.1103/Phys Rev C.79.054614 . URL http://link.aps.org/doi/10.1103/Phys Rev C.79.054614 · doi ↗
- 4[4] V. Y. Denisov, A. Khudenko, α 𝛼 \alpha -decay half-lives, α 𝛼 \alpha -capture, and α 𝛼 \alpha -nucleus potential, Atomic Data and Nuclear Data Tables 95 (6) (2009) 815–835.
- 5[5] R. Walker, J. Morgan, E. Beary, M. Smoliar, G. Czamanske, M. Horan, Applications of the 190 Pt- 186 Os isotope system to geochemistry and cosmochemistry, Geochimica et Cosmochimica Acta 61 (22) (1997) 4799–4807.
- 6[6] F. Begemann, K. Ludwig, G. Lugmair, K. Min, L. Nyquist, P. Patchett, P. Renne, C.-Y. Shih, I. Villa, R. Walker, Call for an improved set of decay constants for geochronological use , Geochimica et Cosmochimica Acta 65 (1) (2001) 111 – 121. doi:http://dx.doi.org/10.1016/S 0016-7037(00)00512-3 . URL http://www.sciencedirect.com/science/article/pii/S 0016703700005123 · doi ↗
- 7[7] D. Cook, R. Walker, M. Horan, J. Wasson, J. Morgan, Pt-Re-Os systematics of group IIAB and IIIAB iron meteorites 1 , Geochimica et Cosmochimica Acta 68 (6) (2004) 1413 – 1431. doi:http://dx.doi.org/10.1016/j.gca.2003.09.017 . URL http://www.sciencedirect.com/science/article/pii/S 0016703703006859 · doi ↗
- 8[8] A. Brandon, R. Walker, I. Puchtel, Platinum- Osmium isotope evolution of the earth’s mantle: Constraints from chondrites and Os-rich alloys , Geochimica et Cosmochimica Acta 70 (8) (2006) 2093 – 2103. doi:http://dx.doi.org/10.1016/j.gca.2006.01.005 . URL http://www.sciencedirect.com/science/article/pii/S 0016703706000305 · doi ↗