# A New Torsion Pendulum for Gravitational Reference Sensor Technology   Development

**Authors:** Giacomo Ciani, Andrew Chilton, Stephen Apple, Taiwo Olatunde, Michael, Aitken, Guido Mueller, John W. Conklin

arXiv: 1701.08911 · 2017-06-19

## TL;DR

This paper introduces a highly sensitive torsion pendulum designed for testing ultra-precise inertial sensors, crucial for space-based gravitational wave detection and geodesy, achieving a noise level close to the thermal limit.

## Contribution

The paper presents a novel torsion pendulum with enhanced sensitivity and integrated capacitive and laser readouts for inertial sensor performance evaluation in space applications.

## Key findings

- Achieved a broadband displacement sensitivity of 30 nm/√Hz with capacitive sensors.
- Demonstrated a residual torque noise of about 200 fN/√Hz at 2 mHz.
- Performance is within a factor of 20 of the thermal noise limit.

## Abstract

We report on the design and sensitivity of a new torsion pendulum for measuring the performance of ultra-precise inertial sensors and for the development of associated technologies for space-based gravitational wave observatories and geodesy missions. The apparatus comprises a 1 m-long, 50 um-diameter, tungsten fiber that supports an inertial member inside a vacuum system. The inertial member is an aluminum crossbar with four hollow cubic test masses at each end. This structure converts the rotation of the torsion pendulum into translation of the test masses. Two test masses are enclosed in capacitive sensors which provide readout and actuation. These test masses are electrically insulated from the rest of the cross-bar and their electrical charge is controlled by photoemission using fiber-coupled ultraviolet light emitting diodes. The capacitive readout measures the test mass displacement with a broadband sensitivity of 30 nm / sqrt(Hz), and is complemented by a laser interferometer with a sensitivity of about 0.5 nm / sqrt(Hz). The performance of the pendulum, as determined by the measured residual torque noise and expressed in terms of equivalent force acting on a single test mass, is roughly 200 fN / sqrt(Hz) around 2 mHz, which is about a factor of 20 above the thermal noise limit of the fiber.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/1701.08911/full.md

## Figures

13 figures with captions in the complete paper: https://tomesphere.com/paper/1701.08911/full.md

## References

31 references — full list in the complete paper: https://tomesphere.com/paper/1701.08911/full.md

---
Source: https://tomesphere.com/paper/1701.08911