Magnetic resonance of rubidium atoms passing through a multi-layered transmission magnetic grating
Y. Nagata, S. Kurokawa, A. Hatakeyama

TL;DR
This study investigates the magnetic resonance of rubidium atoms passing through multilayered transmission magnetic gratings, demonstrating potential for high-frequency, narrow-linewidth magnetic resonance spectroscopy.
Contribution
It introduces multilayered magnetic gratings with adjustable magnetization configurations and analyzes their potential to extend frequency bands and narrow resonance linewidths.
Findings
Good agreement between experimental results and calculations.
Multi-layered gratings can produce narrower linewidths at higher frequencies.
Potential to achieve resonance frequencies up to hundreds of PHz.
Abstract
We measured the magnetic resonance of rubidium atoms passing through periodic magnetic fields generated by two types of multilayered transmission magnetic grating. One of the gratings reported here was assembled by stacking four layers of magnetic films so that the direction of magnetization alternated at each level. The other grating was assembled so that the magnetization at each level was aligned. For both types of grating, the experimental results were in good agreement with our calculations. We studied the feasibility of extending the frequency band of the grating and narrowing its resonance linewidth by performing calculations. For magnetic resonance precision spectroscopy, we conclude that the multi-layered transmission magnetic grating can generate periodic fields with narrower linewidths at higher frequencies when a larger number of layers is assembled at a shorter period…
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Magnetic resonance of rubidium atoms passing through a multi-layered transmission magnetic grating
Y Nagata111Present address: Department of Physics, Tokyo University of Science, Shinjuku, Tokyo 162-8601, Japan. Present email address: [email protected], S Kurokawa and A Hatakeyama
Department of Applied Physics, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588, Japan
[email protected] and [email protected]
Abstract
We measured the magnetic resonance of rubidium atoms passing through periodic magnetic fields generated by two types of multi-layered transmission magnetic grating. One of the gratings reported here was assembled by stacking four layers of magnetic films so that the direction of magnetization alternated at each level. The other grating was assembled so that the magnetization at each level was aligned. For both types of grating, the experimental results were in good agreement with our calculations. We studied the feasibility of extending the frequency band of the grating and narrowing its resonance linewidth by performing calculations. For magnetic resonance precision spectroscopy, we conclude that the multi-layered transmission magnetic grating can generate periodic fields with narrower linewidths at higher frequencies when a larger number of layers is assembled at a shorter period length. Moreover, the frequency band of this type of grating can potentially achieve frequencies of up to hundreds of PHz.
††: J. Phys. B: At. Mol. Opt. Phys.
- March 2017
Keywords: Magnetic resonance, Atomic beam, Multi-layered magnetic film, Spectroscopy
1 Introduction
Atomic resonance is usually induced by an electromagnetic wave, such as that generated by a laser or a microwave, and is utilized for the spectroscopic study of atomic properties. Such spectroscopic techniques have contributed toward the broad scientific field seen in the present day [1]. This type of spectroscopy is of great importance and has a high scientific impact.
Atomic resonance, induced not by an electromagnetic wave but instead by a periodic static potential, was predicted and observed decades ago [2, 3, 4]. The resonance of energetic highly charged ions passing through a crystalline periodic electric field has been investigated at the energy levels of the X-ray region [5, 6]. Recently, this technique was applied to the precision spectroscopy of Li-like uranium ions irradiated on a Si crystal to study quantum electrodynamic effects at the 2s energy level [7].
This type of technique can also be applied to the magnetic resonance of atoms using periodic magnetic structures, which were extensively studied for the manipulation of cold atoms [8, 9, 10, 11]. Such resonance was first observed for the Zeeman sub-levels of rubidium (Rb) atoms in an Rb vapor cell, on which a periodic magnetic field was applied using currents [12]. The frequency experienced by the atoms is given by , with denoting the period length of the field and the atomic velocity. In this experiment, a resonance of around kHz was observed for mm and m/s. This resonance is the so-called “motion-induced resonance” (MIR). The relative linewidth of the resonance frequency () depends on the number of periods of the magnetic field felt by the atoms , and its full width at half maximum (FWHM) is approximately .
The magnetic resonance of atoms has been extensively investigated in the microwave region, for example nuclear magnetic moments and hyperfine structures [13, 14]. MIR has advantages compared with the microwave technique. The frequency is continuously and widely tunable by changing . In contrast, the microwave frequency strongly depends on the dimensions of the cavity and cannot be easily changed. The field strength of a periodic magnetic field can be changed by up to a few tenths of T by selecting a ferromagnetic material of residual magnetization T, where and represent the vacuum permeability and magnetization, respectively. This strength is comparable to, or larger than, the magnetic field generated by a superconducting microwave frequency cavity, which is limited by a type II magnetic quench field of, for example, 0.24 T for niobium (Nb) [15].
In recent years, the magnetic transition of a nucleus has been proposed as a candidate for a nuclear clock, with a relative linewidth as low as for a transition energy constrained to between 6.3 and 18.3 eV, and an intensive search for these transitions is underway [16]. MIR, for example, can achieve a transition energy of 10 eV (2.4 PHz) for m/s and nm. If the frequency band of MIR is extended by shortening and the linewidth is narrowed considerably by a larger value of , MIR can be a strong spectroscopic technique for the measurement of magnetic resonance.
As an attempt to increase , MIR was tested with an Rb atomic beam travelling between wire currents that generated a periodic magnetic field for [17] and 10 [18]. The relative linewidths were observed as 4% and 10%, respectively, as expected. However, it is not easy to assemble wires with a period of much less than 1 mm to obtain a shorter . MIR for shorter was demonstrated by using a monolayer transmission magnetic grating with a thin magnetic film having a 150 m line-and-space pattern, to obtain higher frequency resonance [19]. In this experiment, Rb atoms were injected into the grating at an incline from the grating surface with an angle of 10 degrees such that they experienced a few oscillating cycles during passage through the grating. Although it is possible to significantly enhance the resonant frequency, it is difficult to obtain a larger value for .
To address these limitations, in this paper we demonstrate MIR of Rb atoms passing through a multi-layered transmission magnetic grating that was assembled by stacking four layers of magnetic film on top of each other. We compare the experimental results of MIR with the results of our calculations. We then discuss the feasibility of extending the frequency band and narrowing the linewidth with the grating. Our study shows the grating can generate periodic fields with narrower linewidths at higher frequencies by assembling a larger at a shorter , and can be applied to the MIR in terms of the spectroscopy of magnetic resonance with the frequency potentially achieving up to hundreds of PHz.
2 Experiment
Figure 1 shows a conceptual drawing of our experimental setup, which is the same as that used in a previous experiment [19] except for the replacement of a center grating. Rb atoms were prepared in an oven heated up to a temperature of 473 K. An Rb atomic beam was then produced by collimating Rb atoms emerging from the oven with two apertures, whose diameters and separation were 2 mm and 100 mm, respectively. The flux of Rb atoms was expected to be . Two coil magnets that generated a magnetic field up to 2 mT in the beam direction were used to lift the degeneracies of the Zeeman sub-levels of the Rb atoms. The Earth’s magnetic field was cancelled in advance by the use of three axes of magnetic coils (not shown in the figure). The Rb beam was polarized via optical pumping by a circularly polarized pump laser with a wavelength of 780.24 nm through the transition of the line of 85Rb. The power of the pump laser was about 100 , which was strong enough to obtain polarization signals with good signal-to-noise ratio. The velocity of the Rb atoms was optically selected using the Doppler effect from the broad velocity distribution of the thermal beam by laser frequency detuning with an acousto-optic modulator. The Rb beam then passed through a multi-layered transmission magnetic grating. The probe laser, which was also tuned to the transition, was modulated between left- and right-hand circular polarizations at 50 kHz by a photoelastic modulator, before being crossed with an Rb beam and detected by a photodetector. The power of the probe laser was weaker than that of the pump laser and did not affect the signals. If the frequency between Zeeman sub-levels coincides with , MIR is induced and changes the absorption signal of the probe laser light, where is the gyromagnetic ratio and is GHz/T. The modulation signal from the photodetector through a lock-in amplifier is proportional to the polarization of the Zeeman sub-levels in the direction of the probe beam; this polarization is hereafter denoted as . By measuring the signal as a function of from 0 mT to 2 mT, MIR can then be observed.
The magnetic film was produced via vapor deposition of a nickel (Ni) layer with a thickness nm on a 25-m-thick polyimide film with 20 slits fabricated by means of chemical etching and with a slit size of width m and height mm ( direction) at 300 m intervals, as shown in Fig. 2. Each magnetic film was magnetized parallel to the Ni film plane by applying a uniform magnetic field of 0.23 T, which was strong enough to saturate the magnetization. The residual magnetization was calculated from the B-H curve measured by a vibrating sample magnetometer and = 280 mT. The multi-layered transmission magnetic grating in Fig. 2 was assembled by stacking the magnetic films in four layers so that the direction of magnetization alternated with each film, with polyimide sheet spacers inserted between them. The average distance between layers was 243 m, and therefore . Another multi-layered transmission magnetic grating was assembled so that the direction of magnetization of each of the films was aligned. Such aligned magnetization has the advantage that the production procedure is considerably simplified, i.e., magnetic films can be magnetized at the same time after all magnetic films are assembled without the need for alternate stacking. In this case, .
3 Results and Discussion
We calculated the component of the magnetic field along the path of the Rb atoms in a multi-layered transmission magnetic grating for mT in alternate magnetization, as shown in Fig. 3 (a), where we assumed that the height of the slit (the dimension in the direction) was infinity and that the Rb atoms passed along the axis. Blue solid, red dotted, and green dashed-dotted lines show the position dependences of magnetic fields with the position from the slit center , 30, and 60 m, respectively (see Fig. 2). The number of periods was confirmed as 2. As the paths of the Rb atoms lie close to the Ni film, the maximum magnetic field becomes even stronger. The for m is three times larger than that for m.
Figure 3 (b) shows Fourier spectra calculated from the magnetic fields shown in Fig. 3 (a). Different lines show the dependence. The largest component appears at the frequency that corresponds to the first order Fourier component of . Although the magnetic fields in Fig. 3 (a) have different shapes depending on , each of the largest components appears at almost the same frequency.
We measured the velocity dependence of MIR signals induced by a multi-layered transmission magnetic grating with alternate magnetization as a function of , as shown in Fig. 4. Black lines show experimental results from to 408 m/s and are normalized by the number of atoms that depends on in the Maxwellian distribution of the atomic beam. A color map shows the intensity of MIR signals interpolated between the black lines. As is increased, the resonance frequency of the Rb atoms, , becomes higher and thus coincides with for increased . To see this dependence, we draw a dotted line, indicated by the numbers () 1, 3, and 5, showing the resonance condition of . The peaks of the experimental results generally follow the dotted lines well.
Figure 5 shows a typical MIR spectrum selected from Fig. 4 for m/s. The red solid line shows the experimental result. The horizontal axis shows a normalized frequency so that the frequency of the first order Fourier component corresponds to 1. We obtained the largest peak at around 1 and the FWHM was around 0.5, as expected. The blue dotted line in Fig. 5 shows a Fourier spectrum averaged over the different from m to m with 20 segments. In the calculations, we assumed the atomic density was uniform across the slit and edge effects such as van der Waals forces were neglected. The peak height of the first order Fourier component is normalized to the experimental result. The calculation result is in acceptable agreement with the experimental result.
In the above experiment, four films were magnetized independently and stacked alternately. If these films are stacked first and then magnetized at the same time, the procedure for assembling the multi-layered transmission magnetic grating is simplified considerably. Figures 6 (a) and (b) show the magnetic fields of this grating and the Fourier spectra, respectively, while different lines show the dependence. In contrast to Fig. 3 (a), the period length reduces by half (). As the magnetic fields are always positive, the oscillation center of the magnetic field is biased by, for example, mT at . can be defined from and is roughly half, in comparison with the alternate magnetization.
The red solid line in Fig. 7 shows a MIR spectrum for m/s with the multi-layered transmission magnetic grating in aligned magnetization. The axes are the same as in Fig. 5. The blue dotted line shows a Fourier spectrum averaged over in the same way. The Fourier calculation does not agree with the experimental result. The largest peak in the experimental result appears at a frequency much smaller than 1. Considering , Zeeman splitting is changed from to or for . For the first order resonance at mT, mT for mT at , and is around 10% smaller than mT. Therefore this peak is shifted to the lower side. To take into account for various and reproduce the detailed structure of the MIR spectrum, we solved a classical spin dynamics differential equation,
[TABLE]
where is an atomic angular momentum vector and . We calculated the component of averaged over from m to m with 20 segments, , by solving this equation under the initial condition of , as shown by the green dashed-dotted line in Fig. 7, where is biased and normalized to fit the height of the first Fourier component. This calculation agrees with the experimental result much better than the Fourier spectrum.
If the multi-layered transmission magnetic grating is assembled to provide a larger and shorter , its frequency band and relative linewidth are expected to be extended and narrowed, respectively. Assembling a shorter is possible by use of thin magnetic films, as described above. Here, we calculated for the multi-layered transmission magnetic grating with large to investigate the convergence of the relative linewidth. The calculation is performed for the same dimension (see Fig. 2) except for . Figures 8 (a) and (b) show for and mT (4 layers) and and mT (20 layers) gratings with alternate magnetization, respectively. Different thin lines show the dependence for and representing 5 segments in the range from to 75 . A thick line shows the average of these lines. The FWHM of the thick line for is 0.43. It is noted that the peak position is lower than 1 because the peak frequency depends on . For example, if cycles of the sine function are taken to be the periodic magnetic field, the shift is described approximately by calculated with the Fourier transformation. This shift converges quickly with for larger in contrast to the relative linewidth of .
The FWHM for in Fig. 8 (b) is expected to be five times smaller than . However, it is actually 0.13, which is larger than expected. In this case, the thin lines show different shapes depending on and cause the broad linewidth. Therefore, we calculated the Rabi frequency . is the maximum at the half period of the Rabi cycle, which becomes s for mT ( mT) at . On the other hand, the transit time through the grating for is 12 s for a path length of and m/s. Therefore, the half period of the Rabi cycle is too short compared to the transit time. To obtain a narrower linewidth, should be lower for larger and be decreased so that to ensure that the half period of the Rabi cycle is shorter than the transit time. The strength of can be selected by changing the dimension of the grating, even if is fixed. Provided that , at is roughly described by,
[TABLE]
generated by one magnetic dipole in the magnetic film, and is calculated as 0.086 mT for mT, which is larger than the numerical calculation of 0.068 mT. The discrepancy is caused by other magnetic dipoles present in the magnetic film, but is not too large to prevent estimation of the field. From this formula, is adjustable by , , and for fixed . Here, we decreased to 20 mT and calculated, as shown in Fig. 8 (c). The FWHM is 0.084, as expected.
Figures 8 (d) and (e) show in the aligned magnetization direction for and mT (4 layers) and and mT (20 layers) gratings, respectively. Lines are the same as in Fig. 8 (a). The FWHMs of the thick lines in Figs. 8 (d) and (e) are 0.22 and 0.043, respectively, as expected. Although causes a frequency shift of , this shift can be suppressed as for larger , because is basically proportional to , i.e., .
From these measurements and calculations, we conclude that the two types of multi-layered transmission magnetic grating can extend the frequency band by using a short , and can narrow the relative linewidth by stacking layers with large without serious frequency shifts. Considering the ease of manufacturing the gratings, the aligned magnetization for the multi-layered transmission magnetic grating is more efficient than the alternate magnetization. For example, the multi-layered magnetic films can be manufactured by means of depositing the film with alternating layers of magnetic and non-magnetic material, thus potentially achieving on the order of nanometers. This realizes a frequency of up to hundreds of PHz for m/s at a maximum.
4 Conclusions
We measured MIR signals of Rb atoms passing through two types of multi-layered transmission magnetic grating, assembled in respective alternate and aligned magnetization layers, to study the feasibility of extending the resonance frequency band of this grating and narrowing its resonance linewidth. The MIR signal in alternate magnetization was in agreement with a Fourier spectrum. Although the MIR signal in aligned magnetization was observed at a lower frequency than expected due to the bias field , the component of the atomic angular momentum vector calculated with a classical spin dynamics differential equation reproduced the MIR signal reasonably well.
We calculated for the multi-layered transmission magnetic grating with increased . The linewidth could be narrowed by stacking more layers without serious frequency shifts. Considering the ease of manufacturing the gratings, the aligned magnetization for the multi-layered transmission magnetic grating is more efficient than the alternate magnetization. We conclude that the multi-layered transmission magnetic grating can generate periodic fields with narrower linewidths at higher frequencies by assembling a larger at a shorter for the precision spectroscopy of magnetic resonance, and its frequency band potentially achieves frequencies of up to hundreds of PHz.
Acknowledgments
This work was supported by JSPS KAKENHI Grant Numbers JP23244082.
Reference
The reference list from the paper itself. Each links out to its DOI / PubMed record.
- 1[1] W. Demtröder 1995 Laser Spectroscopy (Springer)
- 2[2] Okorokov V V 1965 J. Nucl. Phys. 2 1009 Okorokov V V 1966 Sov. J. Nucl. Phys. 2 719 Okorokov V V 1965 Zh. Eksp. Teor. Fiz. Pis’ma Red. 2 175 Okorokov V V 1965 JETP Lett. 2 111
- 3[3] Hadeishi T, Bickel W S, Garcia J D and Berry H G 1969 Observations of lamb shifts in H using spatially periodic potentials Phys. Rev. Lett. 23 65
- 4[4] Datz S et al 1978 Resonant coherent excitation of channeled ions Phys. Rev. Lett. 40 843
- 5[5] Nakai Y, Nakano Y, Azuma T, Hatakeyama A, Kondo C, Komaki K, Yamazaki Y, Takada E and Murakami T 2008 Dressed atoms in flight through a periodic crystal field: c X-VUV double resonance Phys. Rev. Lett. 101 113201
- 6[6] Nakano Y, Kondo C, Hatakeyama A, Nakai Y, Azuma T, Komaki K, Yamazaki Y, Takada E and Murakami T 2009 Polarization control in three-dimensional resonant coherent excitation Phys. Rev. Lett. 102 085502
- 7[7] Nakano Y et al 2013 Resonant coherent excitation of the lithiumlike uranium ion: a scheme for heavy-ion spectroscopy Phys. Rev. A 87 060501
- 8[8] Roach T M et al 1995 Realization of a Magnetic Mirror for Cold Atoms Phys. Rev. Lett. 75 629