Timing Performance of a Double Layer Diamond Detector
M. Berretti, E. Bossini, M. Bozzo, V. Georgiev, T. Isidori, R., Linhart, N. Turini

TL;DR
This paper reports on a double-layer diamond detector that significantly improves timing precision over single-layer detectors, based on experimental results from CERN particle beam tests.
Contribution
It introduces a novel double-layer diamond detector configuration and demonstrates its enhanced timing performance through experimental measurements.
Findings
Timing precision improved by a factor of 1.6-1.7
First measurements performed on CERN particle beam
Prototype design successfully tested in experimental conditions
Abstract
In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This note describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement on the timing precision of a factor of 1.6-1.7 with respect to a single layer scCVD diamond detector.