A Cockcroft-Walton PMT base with signal processing circuit
Yin Jun, Wang Yanyu, Zhang Yapeng

TL;DR
This paper presents a compact, low-power Cockcroft-Walton PMT base with integrated signal processing for muon detection, suitable for portable, battery-powered systems.
Contribution
It introduces a surface mount 14-PIN design combining high voltage supply and signal processing in a small, portable package.
Findings
Successful prototype testing demonstrated reliable operation.
The system operates on +5V DC with low power consumption.
The design is compact and suitable for mobile muon detectors.
Abstract
Design a surface mount 14-PIN Cockcroft-Walton photomultiplier tube base for a muon detector, which provides both high voltage power supply and signal processing. The whole system, including the detector, adopts a +5V DC power input, and features as tiny size, low power-consumption and good portability, extremely well meeting the requirements of the power supply with a battery on a mobile workstation. Detailed descriptions and test results of a prototype are presented.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsParticle Detector Development and Performance · Radiation Detection and Scintillator Technologies · Neutrino Physics Research