SNO+ scintillator cocktail studies using an ${}^{90}$Y source
Evelina Arushanova, Jeanne R. Wilson

TL;DR
This paper details the development and testing of a ${}^{90}$Y calibration source for scintillator cocktails, including manufacturing procedures and experimental results from two laboratories.
Contribution
It introduces a new ${}^{90}$Y calibration source and demonstrates its effectiveness through experimental validation at two different institutions.
Findings
Successful manufacturing of the ${}^{90}$Y source
Effective calibration demonstrated in small and large scintillator samples
Consistent results across different laboratory setups
Abstract
We present the design of an Y calibration source and its manufacturing procedure, that has been implemented in the University of Sussex radioactive laboratory. The radioactive source was first tested at the University of Sussex using a small scintillator cocktail sample. Further measurements were performed at the University of Pennsylvania using a larger volume of the scintillator cocktail. The results of both studies are presented and discussed.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsNeutrino Physics Research · Radiation Detection and Scintillator Technologies · Atomic and Subatomic Physics Research