Tuner control system of spoke012 SRF cavity for C-ADS injector I at IHEP
Na Liu, Yi Sun, Guang-Wei Wang, Zheng-Hui Mi, Hai-Ying Lin, Qun-Yao, Wang, Rong Liu, Xin-Peng Ma

TL;DR
This paper presents a newly developed tuner control system for spoke SRF cavities at IHEP, demonstrating successful implementation and precise tuning during proton beam commissioning.
Contribution
Introduction of a novel tuner control system for spoke SRF cavities with successful experimental validation at IHEP.
Findings
Achieved a cavity tuning phase error of 0.7 degrees
Successfully implemented the tuner controller for the first time
Demonstrated effective tuning during proton beam commissioning
Abstract
A new tuner control system of spoke superconducting radio frequency (SRF) cavity has been developed and applied to cryomodule I (CM1) of C-ADS injector I at IHEP. We have successfully implemented the tuner controllerfor the first time and achieved a cavity tuning phase error of 0.7degrees (about 4 Hz peak to peak) in the presence of electromechanical coupled resonance. This paper will present the preliminary experimental results based on the new tuner controller under proton beam commissioning.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.