Measurement of spark probability of GEM detector for CBM muon chamber (MUCH)
S. Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos, J. Hehner, V., Kleipa, T. Morhardt, C. J. Schmidt, H. R. Schmidt, J. Wiechula

TL;DR
This paper investigates the stability of triple GEM detectors in high-energy shower environments by measuring and comparing their spark probabilities in shower conditions and pion beam conditions.
Contribution
It provides the first comparative measurement of GEM detector spark probabilities in shower versus pion beam environments.
Findings
Spark probability is higher in shower environments.
GEM detectors maintain stability with acceptable spark rates.
Results inform detector operation in high-energy physics experiments.
Abstract
The stability of triple GEM detector setups in an environment of high energetic showers is studied. To this end the spark probability in a shower environment is compared to the spark probability in a pion beam.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.