Status of the warm front end of PXIE
A. Shemyakin, M. Alvarez, R. Andrews, C. Baffes, A. Chen, B. Hanna, L., Prost, G. Saewert, V. Scarpine, J. Steimel, D. Sun (Fermilab) D. Li (LBNL,, Berkeley) R. D'Arcy (U. Coll. London, Fermilab)

TL;DR
This paper reports on the current status and commissioning results of the warm front end components of PXIE, a test accelerator for Fermilab's superconducting linac upgrade, including the ion source, LEBT, RFQ, and MEBT.
Contribution
It provides detailed updates on the development, assembly, and commissioning progress of the PXIE warm front end components, highlighting recent results and ongoing developments.
Findings
Commissioning results of the partially assembled LEBT.
Status update on RFQ manufacturing.
Development progress of the MEBT chopping system.
Abstract
A CW-compatible, pulsed H- superconducting linac is envisaged as a possible path for upgrading Fermilab's injection complex. To validate the concept of the front- end of such a machine, a test accelerator (a.k.a. PXIE) is under construction. The warm part of this accelerator comprises a 10 mA DC, 30 keV H- ion source, a 2m-long LEBT, a 2.1 MeV CW RFQ, and a 10-m long MEBT that is capable of creating a large variety of bunch structures. The paper will report commissioning results of a partially assembled LEBT, status of RFQ manufacturing, and describe development of the MEBT, in particular, of elements of its chopping system.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsCalibration and Measurement Techniques