RF Test Results from Cryomodule 1 at the Fermilab SRF Beam Test Facility
E. Harms, K. Carlson, B. Chase, E. Cullerton, A. Hocker, C. Jensen, P., Joireman, A. Klebaner, T. Kubicki, M. Kucera, A. Legan, J. Leibfritz, A., Martinez, M. McGee, S. Nagaitsev, O. Nezhevenko, D. Nicklaus, H. Pfeffer, Y., Pischalnikov, P. Prieto, J. Reid, W. Schappert

TL;DR
This paper reports on the testing results and lessons learned from Cryomodule 1 at Fermilab's SRF Beam Test Facility, providing insights for future cryomodule testing and operation.
Contribution
It presents detailed RF test results of Cryomodule 1 and discusses lessons learned to improve future cryomodule testing at Fermilab.
Findings
Successful RF testing of individual cavities and the full cryomodule.
Identified key issues and solutions during testing.
Insights to optimize future cryomodule performance.
Abstract
Powered operation of Cryomodule 1 (CM-1) at the Fermilab SRF Beam Test Facility began in late 2010. Since then a series of tests first on the eight individual cavities and then the full cryomodule have been performed. We report on the results of these tests and lessons learned which will have an impact on future module testing at Fermilab.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsParticle accelerators and beam dynamics · Superconducting Materials and Applications · Particle Accelerators and Free-Electron Lasers