CLIC Detector Main Solenoid Design & Status Report
Benoit Cur\'e, Andrea Gaddi, Alain Herve

TL;DR
This paper discusses the design and status of the main solenoid system for the CLIC detector, including its components, operational scenarios, and key design parameters.
Contribution
It provides a comprehensive overview of the CLIC detector's main solenoid design, highlighting recent developments and the integration of auxiliary systems.
Findings
Design parameters of the main solenoid are detailed.
Operational scenarios like push-pull are considered.
System status and future plans are summarized.
Abstract
The magnet system for the CLIC Detector concepts is composed of the central solenoid in combination with the two forward anti-solenoids and the ancillary systems necessary for their operation, including the so-called push-pull scenario, allowing the quick exchange of the two detectors on the beam line. An overview of the design parameters of the detector main solenoids is presented hereafter.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsParticle Accelerators and Free-Electron Lasers · Particle accelerators and beam dynamics · Gyrotron and Vacuum Electronics Research