Hom and FP Coupler Design for the NLSF High Gradient SC Cavity
N. Juntong, R.M. Jones

TL;DR
This paper presents the design and validation of HOM and FP couplers for a novel NLSF cavity, utilizing ILC baseline couplers and multiple simulation methods to ensure accurate external quality factor calculations.
Contribution
It introduces a specific design approach for HOM and FP couplers tailored for the NLSF cavity, validated through simulation tools.
Findings
Validated external quality factor calculations using multiple simulation methods.
Design approach tailored for NLSF cavity couplers.
Use of ILC baseline couplers in the design process.
Abstract
The design of both higher order mode (HOM) and fundamental power (FP) couplers for a unique New Low Surface Field (NLSF) cavity is presented. Here we present a study which uses ILC baseline couplers. The Balleyguier method of calculating external quality factor is used and the results validated using both Microwave studio and HFSS.
Peer Reviews
No public reviews on file for this paper yet. If you reviewed it on a platform where reviews are public (OpenReview, ICLR, NeurIPS, ICML), you can paste yours below so the community can read it here.
Videos
No videos yet. Explain this paper in a talk, walkthrough, or lecture? Add one.
Taxonomy
TopicsParticle accelerators and beam dynamics · Gyrotron and Vacuum Electronics Research · Particle Accelerators and Free-Electron Lasers