# XMM-{\em Newton} and FUSE Tentative Evidence for a WHIM filament along   the Line of Sight to PKS~0558-504

**Authors:** F. Nicastro, Y. Krongold, D. Fields, M.L. Conciatore, L. Zappacosta,, M. Elvis, S. Mathur, I. Papadakis

arXiv: 0911.4504 · 2015-05-14

## TL;DR

This paper reports tentative evidence for a warm-hot intergalactic medium filament along the line of sight to PKS 0558-504, combining X-ray and UV data to detect and analyze a potential OVIII absorption feature.

## Contribution

First combined detection of OVIII X-ray absorption and broad HI Lyβ in a single system, suggesting a WHIM filament with estimated temperature and metallicity.

## Key findings

- Detection of OVIII Kα at z=0.117 with 2.8σ significance in X-ray data.
- Broad HI Lyβ absorption at a consistent redshift with 4.1σ significance.
- Estimated metallicity of 1-4% solar for the absorber.

## Abstract

We present a possible OVIII X-ray absorption line at $z=0.117 \pm 0.001$ which, if confirmed, will be the first one associated with a broad HI Ly$\beta$ (BLB: FWHM=$160^{+50}_{-30}$ km s$^{-1}$) absorber. The absorber lies along the line of sight to the nearby ($z=0.1372$) Seyfert 1 galaxy PKS~0558-504, consistent with being a WHIM filament. The X-ray absorber is marginally detected in two independent XMM-Newton spectra of PKS~0558-504, a long $\sim 600$ ks Guest-Observer observation and a shorter, $\sim 300$ ks total, calibration observation, with a combined single line statistical significance of 2.8$\sigma$ (2.7$\sigma$ and 1.2$\sigma$ in the two spectra, respectively). When fitted with our self-consistent hybrid-photoionization WHIM models, the combined XMM-{\em Newton} spectrum is consistent with the presence of OVIII K$\alpha$ at $z=(0.117 \pm 0.001)$. This model gives best fitting temperature and equivalent H column density of the absorber of log$T=6.56_{-0.17}^{+0.19}$ K, and logN$_H=(21.5 \pm 0.3) (Z/Z_{0.01\odot})^{-1}$ cm$^{-2}$. The statistical sigificance of this single X-ray detection is increased by the detection of broad and complex HI Ly$\beta$ absorption in archival FUSE spectra of PKS~0558-504, at redshifts $z=0.1183 \pm 0.0001$ consistent with the best-fitting redshift of the X-ray absorber. The single line statistical significance of this line is 4.1$\sigma$ (3.7$\sigma$ if systematics are considered), and thus the combined (HI+OVIII) statistical significance of the detection is of 5.0$\sigma$.   The detection of both metal and H lines at a consistent redshift, in this hot absorbing system, allows us to speculate on its metallicity. By associating the bulk of the X-ray absorber with the BLB line detected in the FUSE spectrum at $z_{BLB}=0.1183 \pm 0.0001$, we obtain a metallicity of 1-4\% Solar.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/0911.4504/full.md

## Figures

19 figures with captions in the complete paper: https://tomesphere.com/paper/0911.4504/full.md

## References

39 references — full list in the complete paper: https://tomesphere.com/paper/0911.4504/full.md

---
Source: https://tomesphere.com/paper/0911.4504