# Response of Unruh-DeWitt detector with time-dependent acceleration

**Authors:** Dawood Kothawala, T. Padmanabhan

arXiv: 0911.1017 · 2014-11-20

## TL;DR

This paper investigates how an Unruh-DeWitt detector's response varies with time-dependent acceleration, revealing subtle effects and discontinuities in the thermal spectrum when acceleration changes slowly.

## Contribution

It extends the understanding of detector responses to non-constant accelerations, showing that even slow changes can modify the spectrum at linear order.

## Key findings

- Detector response matches a slowly varying temperature when g(	au) is much larger than 	ext{inverse frequency}.
- Spectrum is modified at linear order in 	ext{rate of change of acceleration} even when frequency probes scales much smaller than the inverse acceleration.
- Discontinuity exists in detector behavior when 	ext{rate of change of acceleration} approaches zero, affecting the thermal nature of the spectrum.

## Abstract

It is well known that a detector, coupled linearly to a quantum field and accelerating through the inertial vacuum with a constant acceleration $g$, will behave as though it is immersed in a radiation field with temperature $T=(g/2\pi)$. We study a generalization of this result for detectors moving with a time-dependent acceleration $g(\tau)$ along a given direction. After defining the rate of excitation of the detector appropriately, we evaluate this rate for time-dependent acceleration, $g(\tau)$, to linear order in the parameter $\eta = \dot g / g^2$. In this case, we have three length scales in the problem: $g^{-1}, (\dot g/g)^{-1}$ and $\omega^{-1}$ where $\omega$ is the energy difference between the two levels of the detector at which the spectrum is probed. We show that: (a) When $\omega^{-1} \ll g^{-1} \ll (\dot g/g)^{-1}$, the rate of transition of the detector corresponds to a slowly varying temperature $T(\tau) = g(\tau)/2 \pi $, as one would have expected. (b) However, when $ g^{-1}\ll \omega^{-1} \ll (\dot g/g)^{-1}$, we find that the spectrum is modified \textit{even at the order $\mathcal{O}(\eta)$}. This is counter-intuitive because, in this case, the relevant frequency does not probe the rate of change of the acceleration since $(\dot g/g) \ll \omega$ and we certainly do not have deviation from the thermal spectrum when $\dot g =0$. This result shows that there is a subtle discontinuity in the behaviour of detectors with $\dot g = 0$ and $\dot g/g^2$ being arbitrarily small. We corroborate this result by evaluating the detector response for a particular trajectory which admits an analytic expression for the poles of the Wightman function.

## Full text

_Full body text omitted from this summary view._ Fetch the complete paper as Markdown: https://tomesphere.com/paper/0911.1017/full.md

## References

15 references — full list in the complete paper: https://tomesphere.com/paper/0911.1017/full.md

---
Source: https://tomesphere.com/paper/0911.1017